Ventricular capture management is an automatic pacing threshold adjustment algorithm that automatically measures pacing threshold through detection of the evoked response after a pacing stimulus. Although it is principally designed to save device battery under the maintenance of the patient׳s safety, we experienced a rare case with serious pacing failure due to a weakness of this algorithm. This pacing failure might be explained by a large variation in the ventricular pacing threshold depending on the atrioventricular interval and daily variation of pacing threshold and concomitant steroid use in this patient.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5729025PMC
http://dx.doi.org/10.1016/j.joa.2017.05.005DOI Listing

Publication Analysis

Top Keywords

pacing threshold
20
pacing failure
12
pacing
9
automatic pacing
8
threshold adjustment
8
threshold
5
failure caused
4
caused automatic
4
adjustment system
4
system ventricular
4

Similar Publications

Objective: To evaluate systematically the feasibility and effectiveness of His Bundle Pacing (HBP) for cardiac resynchronization therapy.

Methods: A comprehensive search was conducted in PubMed, EMbase, WOS, Cochrane Library, Medline, and SinoMed for studies published between December 2003 and December 2023. Primary clinical outcomes included implantation success, QRS wave duration, pacing threshold, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDD), New York Heart Association (NYHA) cardiac function class, and complications.

View Article and Find Full Text PDF

The Accuracy of Cardiac Surface Conduction Velocity Measurements.

JACC Clin Electrophysiol

December 2024

The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.

Background: Conduction velocity (CV) is a measure of the health of myocardial tissue. It can be measured by taking differences in local activation times from intracardiac electrodes. Several factors introduce error into the measurement, among which ignoring the 3-dimensional aspect is a major detriment.

View Article and Find Full Text PDF

Our study evaluated the efficacy and feasibility of left bundle branch area pacing (LBBAP) compared to right ventricular outflow tract septal pacing (RVOSP). We conducted a prospective, single-center, observational study involving 200 consecutive patients who required pacemaker implantation. The patients were divided into two groups (LBBAP and RVOSP), with 100 patients in each group.

View Article and Find Full Text PDF

Background: Left bundle branch area pacing (LBBAP) is a new technique for patients with atrioventricular block (AVB) and preserved left ventricular ejection fraction (LVEF), potentially offering better cardiac function than right ventricular pacing (RVP).

Methods: We searched databases and registries for studies that compared LBBAP with RVP in patients with AVB and preserved LVEF. We extracted data on various outcomes and pooled the effect estimates using random-effects models.

View Article and Find Full Text PDF

Sudden unexpected death in epilepsy (SUDEP) is a devastating complication of epilepsy with possible sex-specific risk factors, although the exact relationship between sex and SUDEP remains unclear. To investigate this, we studied Kcna1 knockout (Kcna1) mice, which lack voltage-gated Kv1.1 channel subunits and are widely used as a SUDEP model that mirrors key features in humans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!