Case: A forty-seven-year-old woman presented with recurrent urinary tract infections eleven years after open fixation of a pelvic ring injury. Cystoscopy revealed that the pelvic reconstruction plate had eroded into the bladder, likely the source of the recurrent infections. Following removal of the involved pelvic hardware and repair of the bladder, the patient had no further urinary tract infections.

Conclusion: Operative fixation of osseous pelvic injuries places metal implants in proximity to the bladder. Late erosion of hardware into the bladder can occur. A low threshold for urological work-up should be maintained for recurrent genitourinary symptoms in these patients.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.CC.N.00247DOI Listing

Publication Analysis

Top Keywords

urinary tract
12
pelvic reconstruction
8
reconstruction plate
8
recurrent urinary
8
tract infections
8
pelvic
5
bladder
5
delayed erosion
4
erosion pelvic
4
plate bladder
4

Similar Publications

Background Sodium-glucose co-transporter 2 (SGLT2) inhibitors are an emerging treatment for type 2 diabetes mellitus (T2DM). The effect and tolerability of SGLT2 inhibitors in patients with T2DM, especially related risk factors and susceptible populations, are an area of ongoing research. Aim The aim of this study was to evaluate the tolerability of SGLT2 inhibitors, particularly the risk associated with urogenital infection, in patients with T2DM.

View Article and Find Full Text PDF

Background: Clinicians need to prescribe antibiotics in a way that adequately treats infections, while simultaneously limiting the development of antibiotic resistance (ABR). Although there are abundant guidelines on how to best treat infections, there is less understanding of how treatment durations and antibiotic types influence the development of ABR. This study adopts a self-controlled case study (SCCS) method to relate antibiotic exposure time to subsequent changes in resistance patterns.

View Article and Find Full Text PDF

Background: The Toumai MT-1000 Endoscopic Surgical System is a newly developed surgical robot from China. This study evaluates its feasibility, safety, and effectiveness for various urologic procedures based on our single-center experience.

Methods: From October 2023 to January 2024, 20 urologic procedures were performed at Peking University First Hospital using the Toumai MT-1000 system.

View Article and Find Full Text PDF

Background: Fibroepithelial polyp (FEP) in the renal pelvis is a rare benign tumor of the urinary tract. Treatment of such diseases varies from local resection to radical nephroureterectomy, either by open or endoscopic surgery. This study aims to show our successful experience in percutaneous endoscopic resection of FEP.

View Article and Find Full Text PDF

Background: The treatment of transplant ureteral stricture (TUS) has been a great challenge, and there is limited experience with indocyanine green (ICG) fluorescence-guided robotic Boari flap-pelvis anastomosis to identify ureteral stenosis segments (especially long-segment) and their postoperative blood supply. We report case series of ureteral strictures treated with ICG fluorescence-guided robotic Boari flap-pelvis anastomosis in our center.

Case Description: We retrospectively collected clinical data of six patients diagnosed with long-segment even full-length TUS who underwent robotic Boari flap-pelvis anastomosis with the assistance of modified distribution of robotic ports and ICG fluorescence between June 2022 and June 2024, focusing on postoperative renal function, stenosis recurrence, and urinary fistulae.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!