Background: Sentinel lymph node (SLN) biopsy represents a well-established diagnostic tool for the assessment of lymphatic metastasis. Correct pre- and intraoperative visualization of SLN is of the utmost importance to ensure the safety and feasibility of the procedure. Aim of this study was to evaluate the diagnostic value of preoperative SLN imaging via single photon emission computed tomography/computed tomography (SPECT/CT) and planar scintigraphy in patients with penile carcinoma with nonpalpable inguinal lymph nodes.
Materials And Methods: After peritumoral intradermal tracer injection (150MBq/4.05mCi Tc-99m nanocolloid), we acquired planar scintigraphies including indirect body contouring using a twin head gamma camera. Subsequently we acquired SPECT/CT images of the abdomen via a hybrid system. Prospective evaluation of 52 groins in 26 examined patients was done for all image files obtained with both techniques by 2 trained experts in consensual assessment.
Results: A total of 71 SLNs in 37 groins were identified by means of planar scintigraphy. In these images, no radiolabeled lymph nodes were visualized in 15 out of 52 groins (28.8%). The SPECT/CT images showed a total of 82 SLNs in 42 groins. In 19.2% (10 of the 52 groins), there was no visualization of lymph nodes in SPECT/CT. 8 SLNs in 7 groins that were visualized in the planar technique were found to be false positive by SPECT/CT. In total, 19 SLNs in 16 groins that were overlooked by planar imaging could only be detected by SPECT/CT. In contrast to planar scintigraphy, SPECT/CT imaging enabled clear and precise anatomical localization of SLNs in all 42 groins where radiolabeled SLNs were visible. Even under consideration of all lymphatic drainage regions, statistical evaluation showed a significantly higher number of detected SLNs with SPECT/CT in comparison to the planar technique (P = 0.0022).
Conclusion: In these patients SPECT/CT is capable of visualizing SLNs that cannot be detected with planar imaging. The SPECT/CT technique reduces the number of false positive findings from planar SLN imaging and is able to show anatomic SLN localization more precisely. If possible, preoperative SLN imaging should be performed by means of the SPECT/CT technique in patients with this tumor entity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.urolonc.2017.11.012 | DOI Listing |
Eur J Surg Oncol
December 2024
Melanoma Institute Australia, The University of Sydney, Sydney, NSW, Australia; The University of Sydney, Faculty of Medicine and Health, Sydney, NSW, Australia; Royal Prince Alfred Hospital, Department of Melanoma and Surgical Oncology & Institute of Academic Surgery (IAS), Sydney, NSW, Australia. Electronic address:
Background: Although most melanomas drain to the more common major lymph node basins (axilla, groin, neck), rarely they drain to deep SLN locations such as intra-abdominal and intra-thoracic (including intercostal and internal mammary) sites, which pose a higher surgical risk and complexity for procurement. Our study is aimed at determining the rate of positivity and likelihood of recurrence in these nodal sites to guide management decisions for patients with truncal melanomas which drain to these 'deep' SLN locations.
Methods: Retrospective data collected between May 2008 and May 2022 including all patients with truncal melanomas who underwent lymphoscintigraphy resulting in the identification of deep SLNs in intra-abdominal and intra-thoracic sites were included.
World J Urol
September 2024
Department of Surgical Oncology, Basavatarakam Indo-American Cancer Hospital and Research Institute, Hyderabad, Telangana, India.
Aim: The primary aim of this study was to validate the reliability, sensitivity and safety profile of novel combination of ICG- methylene blue dye as an SN tracer for PeCa.
Methods: This is a validation and non-randomised prospective observational study involving 25 patients (50 inguinal basins) who underwent SLNB where in ICG and methylene blue were used for localisation. The patients with clinically node negative groins were recruited in the study.
Heliyon
August 2024
Department of Obstetrics and Gynecology, The First Affiliated Hospital (Southwest Hospital), Army Medical University (Third Military Medical University), Chongqing, China.
Objective: Carbon nanoparticle (CNP)-guided sentinel lymph node biopsy (SLNB) has been extensively adopted as a cost-effective and highly efficient method for tracing malignant tumors except for those associated with vulvar cancer. The current study aimed to validate the feasibility and efficacy of CNPs in tracking sentinel lymph nodes (SLNs) in patients with early vulvar cancer.
Methods: We retrospectively reviewed patients with vulvar cancer at our institution from January 2016 to April 2022 who were pathologically diagnosed and underwent SLNB or inguinofemoral lymphadenectomy (IFLND).
Gynecol Oncol
August 2024
Hospital Universitario Donostia, San Sebastián, Spain.
Objectives: Sentinel lymph node (SLN) detection with superparamagnetic iron oxide (SPIO) nanoparticles has been widely studied and standardized for breast and prostate cancer, but there is scarce evidence concerning its use in vulvar cancer. The objective of this study was to compare SLN detection using a SPIO tracer injected at the time of the surgery detected by a magnetometer, with the standard procedure of using a technetium 99 radioisotope (Tc99) detected by a gamma probe, in patients with vulvar cancer.
Methods: The SPIO vulvar cancer study was a single-center prospective interventional non-inferiority study of SPIO compared to Tc99, conducted between 2016 and 2021 in patients who met the GROINSS-V study inclusion criteria for selective sentinel lymph node dissection in vulvar cancer.
Int J Surg
May 2024
Department of Thoracic and Cardiovascular Surgery, Korea University Guro Hospital, Korea University College of Medicine.
Background: This study aimed to evaluate the effectiveness of neo-mannosyl human serum albumin-indocyanine green (MSA-ICG) for detecting metastatic lymph node (LN) and mapping sentinel lymph node (SLN) using mouse footpad uterine tumor models. Additionally, the authors assessed the feasibility of MSA-ICG in SLN mapping in rabbit uterine cancer models.
Materials And Methods: The authors compared the LN targeting ability of MSA-ICG with ICG.