[Contribution of computer-aided design for the conception of custom-made implants in Pectus Excavatum surgical treatment. Experience of the Nantes plastic surgery unit].

Ann Chir Plast Esthet

Service de chirurgie plastique et reconstructrice, hôpital Hôtel-Dieu, centre des brûlés, CHU de Nantes, 44093 Nantes Cedex 01, France. Electronic address:

Published: February 2018

AI Article Synopsis

Article Abstract

Introduction: Pectus excavatum is the most common congenital chest malformation and is a common reason for consultation in plastic surgery. Our attitude is most often a filling of the depression with a custom-made silicone prosthesis. The objective of this work was to evaluate the interest of computer-aided design (CAD) of implants compared to the conventional plaster molds method.

Patients And Methods: We have collected all the cases of custom-made silicone implants to treat funnel chests in our plastic surgery department. The quality of the results was evaluated by the patient, and in a blind manner by the surgical team using photographs and standardized surveys. The pre-operative delays, the operating time and length of hospital stays, the number of surgical recoveries, and the post-operative surgical outcomes were recorded.

Results: Between 1990 and 2016, we designed 29 silicone thoracic implants in our department. Before 2012, implants were made from plaster chest molds (n=13). After this date, implants were designed by CAD (n=16). Patients rated their results as "good" or "excellent" in 77% and 86% of cases respectively in the plaster and CAD groups. The surgical team's ratings for CAD implant reconstructions were better than in the plaster group: 8.17 versus 6.96 (P=0.001). CAD implants were significantly less detectable than the plaster group implants. The operating time was reduced in the CAO group: 60.2 compared to 74.7minutes in the plaster group (P=0.04), as was the length of hospitalization: 3.5 versus 5.3 days (P=0.01). There were no significant differences between the two groups in terms of post-operative complications.

Conclusion: The management of pectus excavatum by a custom-made silicone implant is a minimally invasive method that provides good cosmetic results. The design of these implants is facilitated and qualitatively improved by CAD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.anplas.2017.11.006DOI Listing

Publication Analysis

Top Keywords

pectus excavatum
12
plastic surgery
12
custom-made silicone
12
plaster group
12
implants
9
computer-aided design
8
cad implants
8
operating time
8
cad
6
plaster
6

Similar Publications

Background And Aims: Pectus carinatum (PC) is the second most common deformity of the anterior chest wall, resulting in detrimental effects on body image and quality of life. This study evaluated the safety, effectiveness, and factors associated with the treatment of PC using a sandwiched bar and screw fixation system, first performed in Vietnam at the University Medical Center Ho Chi Minh City in 2016.

Methods: This retrospective cohort study was conducted from March 2016 to February 2023 in patients with PC and PC-mixed pectus excavatum (PE) deformities.

View Article and Find Full Text PDF

Background: Pectus excavatum (PE) can cause cardiopulmonary compression with a wide range of symptoms and psychosocial effects. Few validated surveys assess the extensive symptomatology of the adult pectus population. A comprehensive symptom survey was developed and validated with outcomes presented.

View Article and Find Full Text PDF

Background And Objective: Pectus excavatum is a common congenital chest wall abnormality characterized by a concave appearance of the chest, and minimally invasive repair of pectus excavatum (MIRPE) is the surgical treatment of choice. A rapidly growing field of research is pain management in children undergoing MIRPE, with many shifts in practice occurring over the last decade. The primary objectives of this narrative review are to describe current methods of perioperative pain management and the development of enhanced recovery after surgery (ERAS) to improve the experience of patients undergoing MIRPE.

View Article and Find Full Text PDF

Background: Most patients with chest wall deformities have a negative body image, which affects their self-esteem and quality of life (QoL).

Objectives: The aim of this study was to evaluate changes in patients' QoL after minimally invasive repair of pectus excavatum (MIRPE).

Material And Methods: A prospective, single-center study was conducted between 2019 and 2023.

View Article and Find Full Text PDF

Introduction: Pain control following Nuss thoracoplasty remains a challenge. Cryoanalgesia of the intercostal nerves has been demonstrated to reduce postoperative pain in these patients. The objective of this study was to understand how and how widely cryoanalgesia is used in pediatric patients undergoing funnel chest surgery in Spain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!