Case: A 40-year-old woman presented to the emergency department with a comminuted fracture of the patella with separation of the bone fragments. The patient underwent an open reduction and osteosynthesis using medial and lateral 2.0-mm nonlocking plates, which subsequently led to pain in the anterior and posterior aspects of the knee.
Conclusion: In this patient, bicolumnar nonlocking plating was unable to adequately resist the tensile forces of the extensor mechanism. We believe that the probable cause of failure was an insufficient neutralization of the tensile forces exerted by the extensor mechanism. Because of the substantial forces acting on the patella, a method of converting these tensile forces into compressive forces is very beneficial, as seen with anterior tension-band wiring. Although we used nonlocking plates in our patient, we believe that locking-plate fixation placed along the medial and lateral columns also would have had a biomechanical disadvantage in dispersing the tensile forces exerted by the extensor mechanism.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.CC.16.00044 | DOI Listing |
BMC Oral Health
January 2025
Affiliated Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou, People's Republic of China.
Objective: The aim of this study was to establish a three-dimensional finite element (FE) hydraulic pressure technique model and compare the biomechanical characteristics of the osteotome technique and the hydraulic pressure technique using three-dimensional finite element analysis (FEA).
Methods: Three FE models were created: the hydraulic pressure technique (M1), the osteotome technique with a Ø 1.6-mm osteotome (M2), and the osteotome technique with a Ø 3.
Macromol Rapid Commun
January 2025
State Key Laboratory of Advanced Fiber Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 200051, China.
Mechanically responsive polymer materials have garnered significant interest due to their unique ability to respond to external forces, leading to groundbreaking applications in visual stress mapping and damage detection. However, their use in fibers remains relatively unexplored. In this study, a mechanoresponsive polymer is synthesized by incorporating a spiropyran (SP) mechanophore into a polyurethane backbone.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Industrial Engineering, Alma Mater Studiorum-University of Bologna, Bologna, Italy.
Background: Transfemoral osseointegrated prostheses, like other uncemented prostheses experience the risk of aseptic loosening and post-operative periprosthetic fractures, with an incidence between 3% and 30%. To date, however, osseointegrated off-the-shelf prostheses are manufactured in a limited number of sizes, and some patients do not meet the strict eligibility criteria of commercial devices. A customized osseointegrated stem was developed and a pre-clinical in vitro investigation of the stem was performed, to evaluate its biomechanical performance.
View Article and Find Full Text PDFSurg Endosc
January 2025
Division of Minimally Invasive and Bariatric Surgery, Penn State Health Milton S. Hershey Medical Center, 500 University Drive, Hershey, PA, 17033, USA.
Background: Defect closure with mesh suture is a novel technique for hernia repair. Originally described as the construction of lightweight macroporous polypropylene mesh strips as a suture material, it is now available as an FDA-approved product. Mesh suture better distributes tensile forces and reduces fascial tearing compared to traditional suture but requires less implanted material and tissue dissection compared to planar mesh.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
January 2025
Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, China.
The most common type of proximal humerus fracture is surgical neck fracture. The purpose of this paper is to study the mechanical mechanism and the effect of bone degeneration on humeral surgical neck fractures. The right humerus finite element models were established based on CT computed tomography.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!