A Short Femoral Stem in Revision Total Hip Replacement: An Alternative Solution for Prosthetic Fracture: A Case Report.

JBJS Case Connect

South Wales Orthopaedic Research Network, Wales, United Kingdom.

Published: August 2018

Case: A 65-year-old farmer re-presented 5 years after sustaining a midshaft prosthetic fracture of a previous long-stem revision hip replacement. He was treated with a proximal-loading short femoral stem, and did not require an extended trochanteric osteotomy for removal of the well-fixed distal implant. He was able to fully bear weight immediately postoperatively, and he remained pain-free without functional loss at the 42-month follow-up.

Conclusion: This use of a modern short-stem prosthesis is a treatment option for a potentially complex prosthetic fracture in highly active patients, and it reduces intraoperative complexity.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.CC.16.00174DOI Listing

Publication Analysis

Top Keywords

prosthetic fracture
12
short femoral
8
femoral stem
8
hip replacement
8
stem revision
4
revision total
4
total hip
4
replacement alternative
4
alternative solution
4
solution prosthetic
4

Similar Publications

Reverse shoulder arthroplasty in revision surgery-Indications and results.

PLoS One

January 2025

Division of Arthroscopic and special Joint Surgery / Sports Injuries, Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Leipzig, Germany.

Background: The number of reverse shoulder arthroplasty (RSA) procedures performed worldwide has increased over the last 10 years, with a corresponding increase in revision shoulder arthroplasty (SRSA). SRSA is often used for post-traumatic revision surgery in cases of infections and failure of anatomical prostheses. Data on outcomes with specific detail for each indication for the prosthetic solution as a secondary treatment are scarce, and inhomogeneous.

View Article and Find Full Text PDF

Pedicle ossification is a rare but significant complication following mandibular reconstruction using a fibular free flap (FFF), a technique widely employed in maxillofacial surgery due to its reliable vascularized bone supply and low donor site morbidity. The FFF supports dental implantation and prosthetic rehabilitation, with its vascularized periosteum enhancing osteogenic potential. Despite these advantages, unexpected ossification of the flap's vascular pedicle may occur, potentially mimicking tumor recurrence and causing diagnostic uncertainty.

View Article and Find Full Text PDF

Full-arch zirconia restorations on implants have gained popularity due to zirconia's strength and aesthetics, yet they are still associated with challenges like structural fractures, peri-implant complications, and design misfits. Advances in CAD/CAM and digital workflows offer potential improvements, but a technique that consistently addresses these issues in fixed, full-arch, implant-supported prostheses is needed. This novel technique integrates a facially and prosthetically driven treatment approach, which is divided into three phases: data acquisition, restoration design, and manufacturing/delivery.

View Article and Find Full Text PDF

: This study aimed to investigate the fracture strength of a novel-designed Zirconia crown before and after access opening, and to evaluate the mode of fracture and the time needed for initial penetration through the crown. : This study involved the design and testing of 60 zirconia crowns, divided into three groups (20 crowns each) to compare different structural designs. Group 1 (Control) used a conventional full zirconia crown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!