Cooperative broadband spin echoes through optimal control.

J Magn Reson

Department of Chemistry, Technical University of Munich, Lichtenbergstr. 4, 85748 Garching, Germany. Electronic address:

Published: January 2018

The Hahn echo sequence is one of the most common building blocks in magnetic resonance, consisting of an excitation pulse and a refocusing pulse. Conventional approaches to improve the performance of echo experiments focused on the optimization of individual pulses, compensating their own imperfections. Here we present an approach to concurrently design both pulses such that they also compensate each others imperfections. The fact that for such cooperative pulses the individual pulses do not need to be perfect provides additional degrees of freedom, resulting in improved overall Hahn echo performance. Single-scan cooperative pulses are compared to conventional approaches by simulations as well as experiments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2017.10.011DOI Listing

Publication Analysis

Top Keywords

hahn echo
8
conventional approaches
8
individual pulses
8
cooperative pulses
8
pulses
5
cooperative broadband
4
broadband spin
4
spin echoes
4
echoes optimal
4
optimal control
4

Similar Publications

Aortic regurgitation is the third most common valve lesion with increasing prevalence secondary to an ageing population. Transthoracic echocardiography plays a vital role in the identification and assessment of aortic regurgitation and proves essential in monitoring severity and determining the timing of intervention. Building on the foundations of previous British Society of Echocardiography (BSE) recommendations, this BSE guideline presents an update on how to approach an echocardiographic assessment of aortic regurgitation.

View Article and Find Full Text PDF

Among the numerous measurements carried out during a well-logging procedure, the Nuclear Magnetic Resonance (NMR) assessment is one of the fundamental analyses in determining the economic viability of a well for the oil industry. Nowadays, two reliable approaches, Wireline Logging (WL) and Logging While Drilling (LWD), stand out. WL comprises the acquisition of NMR data under static conditions.

View Article and Find Full Text PDF

No method of evaluating transthoracic echocardiograms (TTE) image quality (IQ) has been validated. Furthermore, structural echo lab elements impacting IQ are unknown. We sought to develop and validate a TTE IQ grading tool and determine patient and echo lab features associated with IQ.

View Article and Find Full Text PDF

Deuterium metabolic imaging (DMI) is an emerging Magnetic Resonance technique providing valuable insight into the dynamics of cellular glucose (Glc) metabolism of the human brain in vivo using deuterium-labeled (H) glucose as non-invasive tracer. Reliable concentration estimation of H-Glc and downstream synthesized neurotransmitters glutamate + glutamine (Glx) requires accurate knowledge of relaxation times, but so far tissue-specific T and T relaxation times (e.g.

View Article and Find Full Text PDF

Spin coherence phenomena of an = 1/2 copper(II) system in a polyoxometalate with a less-abundant nuclear spin.

Dalton Trans

December 2024

Department of Chemistry, College of Humanities and Sciences, Nihon University, 3-25-40 Sakurajosui, Setagaya-ku, Tokyo 156-8550, Japan.

The spin coherence phenomena of a system consisting of a mononuclear 3d transition metal = 1/2 centre embedded in a polyoxometalate with low nuclear-spin abundance, [(-CH)N]H[SiWOCuZn], have been revealed for the first time. Variable-temperature Hahn-echo experiments using the pulsed electron spin resonance technique showed that its coherence lifetime remains at the submicrosecond level even above 100 K.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!