To understand women's and men's physiological ranges of liver T1rho relaxation time measured with a single breathhold black blood sequence, this healthy volunteer study was conducted in 62 women (mean age, 38.9 y; range, 18-75 y) and 34 men (mean age, 44.7 y; range, 24-80 y). Approval from the institutional ethics committee was obtained. Magnetic resonance imaging was performed with a 3.0T scanner with six spin-lock times of 0, 10, 20, 25, 35, and 50 ms and a single breathhold of 12 s per slice acquisition. Six slices were acquired for each examination. The results demonstrated that the female liver T1rho value ranged between 35.07 and 51.97 ms and showed an age-dependent decrease, with younger women having a higher measurement. The male liver T1rho value ranged between 34.94 and 43.39 ms, with no evidential age dependence. Postmenopausal women had similar liver T1rho values as men. For women, there was a trend that the liver T1rho value could be 4% to 5% lower during the menstrual phase than during the nonmenstrual phase. For both women and men, no evidential association was seen between body mass index and liver T1rho.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/2472630317747198 | DOI Listing |
Rofo
October 2024
Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong.
We aim to evaluate the potential age- and sex-related variations of normative values of spleen T1rho.Two T1rho sequences were used, with one based on fast spin echo sequence (FSE) and the other based on gradient echo sequence (GRE). Spleen and liver FSE T1rho values were measured in 52 healthy volunteers (36 females, 16 males), and spleen and liver GRE T1rho values were measured in 14 healthy volunteers (6 females, 8 males).
View Article and Find Full Text PDFEur Radiol Exp
June 2024
Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany.
Diagnostics (Basel)
May 2024
Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany.
Quantitative MRI techniques such as T2 and T1ρ mapping are beneficial in evaluating knee joint pathologies; however, long acquisition times limit their clinical adoption. MIXTURE (Multi-Interleaved X-prepared Turbo Spin-Echo with IntUitive RElaxometry) provides a versatile turbo spin-echo (TSE) platform for simultaneous morphologic and quantitative joint imaging. Two MIXTURE sequences were designed along clinical requirements: "MIX1", combining proton density (PD)-weighted fat-saturated (FS) images and T2 mapping (acquisition time: 4:59 min), and "MIX2", combining T1-weighted images and T1ρ mapping (6:38 min).
View Article and Find Full Text PDFAbdom Radiol (NY)
June 2024
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Purpose: To investigate the value of imaging parameters derived from T1 relaxation times in the rotating frame (T1ρ or T1rho), diffusion kurtosis imaging (DKI) and intravoxel incoherent motion (IVIM) in assessment of liver fibrosis in rats and propose an optimal diagnostic model based on multiparametric MRI.
Methods: Thirty rats were divided into one control group and four fibrosis experimental groups (n = 6 for each group). Liver fibrosis was induced by administering thioacetamide (TAA) for 2, 4, 6, and 8 weeks.
Magn Reson Imaging
April 2024
Department of Radiology, The First Affiliated Hospital of Chengdu Medical College, No.278, Baoguang Road, Xindu District, Chengdu, Sichuan, China. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!