Background: Research has shown a modest adherence of diagnostic test accuracy (DTA) studies in glaucoma to the Standards for Reporting of Diagnostic Accuracy Studies (STARD). We have applied the updated 30-item STARD 2015 checklist to a set of studies included in a Cochrane DTA systematic review of imaging tools for diagnosing manifest glaucoma.
Methods: Three pairs of reviewers, including one senior reviewer who assessed all studies, independently checked the adherence of each study to STARD 2015. Adherence was analyzed on an individual-item basis. Logistic regression was used to evaluate the effect of publication year and impact factor on adherence.
Results: We included 106 DTA studies, published between 2003-2014 in journals with a median impact factor of 2.6. Overall adherence was 54.1% for 3,286 individual rating across 31 items, with a mean of 16.8 (SD: 3.1; range 8-23) items per study. Large variability in adherence to reporting standards was detected across individual STARD 2015 items, ranging from 0 to 100%. Nine items (1: identification as diagnostic accuracy study in title/abstract; 6: eligibility criteria; 10: index test (a) and reference standard (b) definition; 12: cut-off definitions for index test (a) and reference standard (b); 14: estimation of diagnostic accuracy measures; 21a: severity spectrum of diseased; 23: cross-tabulation of the index and reference standard results) were adequately reported in more than 90% of the studies. Conversely, 10 items (3: scientific and clinical background of the index test; 11: rationale for the reference standard; 13b: blinding of index test results; 17: analyses of variability; 18; sample size calculation; 19: study flow diagram; 20: baseline characteristics of participants; 28: registration number and registry; 29: availability of study protocol; 30: sources of funding) were adequately reported in less than 30% of the studies. Only four items showed a statistically significant improvement over time: missing data (16), baseline characteristics of participants (20), estimates of diagnostic accuracy (24) and sources of funding (30).
Conclusions: Adherence to STARD 2015 among DTA studies in glaucoma research is incomplete, and only modestly increasing over time.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5730182 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0189716 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!