This study was conducted to evaluate the accuracy of implants placed using two different guided implant surgery materials: thermoplastic versus three-dimensionally (3D) printed. A cone beam computed tomography (CBCT) scan previously obtained and selected for single-tooth implant replacement was converted into a Digital Imaging and Communications in Medicine (DICOM) file. All models were planned and exported for printing using BlueSkyBio Plan Software with the DICOM files. A total of 20 3D-printed mandibular quadrant jaws replicating the CBCT were printed by Right Choice Milling, as was the control model to accept the control implant. Previously, 10 thermoplastic and 10 3D-printed surgical guides had been made by the same lab technician at Right Choice Milling. One Nobel Biocare implant with a trilobe connection was placed per guide and replica jaw model pair. Implants were placed using the thermoplastic and 3D-printed surgical guides, representing the two test groups, following the Nobel Biocare guided surgical protocol. A total of 21 CBCT scans were then taken, one for the control implant and one for each test implant. The CBCT volume was converted to a DICOM file and transferred to Invivo5 software version 5.4 (Anatomage). The DICOM file of each test implant was superimposed over the DICOM file of the control. The deviation of the head of the implant, the deviation of the apex of the implant, and the angle of deviation were evaluated from measurements on the superimposition of the control and test implants. Mann-Whitney U test was used to test the null hypotheses at α = .05 and a confidence interval of 95%. Descriptive statistics were used for the average ± standard deviation. The implants placed with the thermoplastic surgical guides showed an average of 3.40 degrees of angular deviation compared to 2.36 degrees for implants placed with the 3D-printed surgical guides (P = .143). The implants placed with the thermoplastic surgical guides showed an average of 1.33 mm of deviation at the head of the implant compared to 0.51 mm for implants placed with the 3D-printed surgical guides (P < 0.001). The implants placed with the thermoplastic surgical guides showed an average of 1.6 mm of deviation at the apex of the implant compared to 0.76 mm for implants placed with the 3D-printed surgical guides (P < .001). There was no significant difference in the angular deviations of implants placed with thermoplastic surgical guides compared to those placed with the 3D-printed surgical guide. However, the locations of the implant head and implant apex were significantly more accurate for the implants placed with the 3D-printed surgical guides compared to those placed with the thermoplastic surgical guides.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/prd.3254 | DOI Listing |
Tzu Chi Med J
July 2024
Neuroscience Spine Center, Taichung Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taichung, Taiwan.
Objectives: Minimally invasive surgery (MIS) has emerged as a promising alternative to conventional open techniques in the management of adolescent idiopathic scoliosis (AIS).
Materials And Methods: This study presents a case series of six patients who underwent MIS for AIS at a spine center, employing a synergistic blend of intraoperative fluoroscopy, cone-beam computed tomography scans, and three-dimensional navigation technology. The surgical procedures were meticulously guided, with a focus on ensuring safety and precision in posterior pedicle fixation.
Cureus
December 2024
Colorectal Surgery, Northeast Georgia Medical Center Braselton, Braselton, USA.
Omental infarction is a rare cause of acute abdomen, often mimicking more common abdominal emergencies such as appendicitis and cholecystitis, presenting significant diagnostic challenges. A 47-year-old male with a history of ulcerative colitis underwent laparoscopic total colectomy with end ileostomy. Postoperatively, he developed severe abdominal pain, chills, nausea, and increased abdominal distension.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Otorhinolaryngology, The Second Affiliated Hospital of Nanchang University, No. 1, Minde Road, Donghu District, Nanchang City, Jiangxi Province Nanchang, 330006, China.
Objective: To study the effect of heart-collateral-based enlightenment words intervention on anxiety and depression in patients following percutaneous coronary intervention (PCI).
Methods: In this class experimental study, one hundred patients who were hospitalized after PCI from May 2020 to October 2021, were included in this interventional study. They were divided into the test group (n = 50) and the control group (n = 50) based on the random number table.
J Cardiothorac Surg
January 2025
Department of Anesthesiology, The First People's Hospital of Chenzhou, Chenzhou, Hunan Province, 423000, China.
Background: Chronic post-surgical pain (CPSP) is a common complication following video-assisted thoracoscopic surgery (VATS) that significantly impacts the quality of life of patients. Although multiple risk factors have been identified, no systematically validated prediction model exists to guide clinical decision-making.
Objectives: This study aimed to develop and validate a risk prediction model for CPSP in patients undergoing VATS for lung cancer.
BMC Endocr Disord
January 2025
Department of Epidemiology and Biostatistics, Isfahan University of Medical Sciences, Isfahan, Iran.
Background: Primary hyperparathyroidism (pHPT) is the third most common endocrine system disorder. Parathyroidectomy (PTx) is the gold standard of care in symptomatic patients. Patients who are not surgical candidates may benefit from percutaneous ethanol ablation, which is a minimally invasive procedure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!