Replacement of a molar with two narrow-diameter dental implants.

J Indian Soc Periodontol

Department of Periodontics, GITAM Dental College and Hospital, Visakhapatnam, Andhra Pradesh, India.

Published: January 2016

Dental implants have demonstrated a high degree of success in the restorations of teeth in partially or completely edentulous patients. However, when the buccolingual width of the edentulous crest is insufficient for the placement of standard sized implants, the use of two or more smaller diameter implants should be considered to avoid the need for invasive reconstruction techniques such as grafting procedures. The present case report describes the replacement of a single mandibular first molar with two narrow-diameter implants, in a 41-year- old male patient. No postoperative complications were reported in the 3-year follow-up period. The placement of two narrow-diameter implants replacing a missing mandibular molar could eliminate the mesiodistal bending, double the support capacity in the buccolingual direction, and minimize stress on the implants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5713093PMC
http://dx.doi.org/10.4103/jisp.jisp_134_16DOI Listing

Publication Analysis

Top Keywords

molar narrow-diameter
8
dental implants
8
mandibular molar
8
narrow-diameter implants
8
implants
7
replacement molar
4
narrow-diameter dental
4
implants dental
4
implants demonstrated
4
demonstrated high
4

Similar Publications

Purpose: This retrospective cohort study aimed to evaluate the survival rates and risk factors associated with Resorbable Blast Media (RBM) surface dental implants. The study involved 1,130 implants placed in 260 patients, with a follow-up ranging from a minimum of 26 months to a maximum of 120 months, for an average of 60 months.

Materials And Methods: 1,130 RBM surface implants with hybrid macro-geometry were placed in 260 patients.

View Article and Find Full Text PDF

Purpose: To compare the prosthetic outcomes of screw-retained monolithic zirconia (Zr) single crowns supported by either narrow-diameter (3.3 mm) or standard-diameter (4.1 mm) tissue-level titanium-zirconia (TiZr) implants in posterior sites.

View Article and Find Full Text PDF

Scientific literature lacks strong support for using narrow diameter implants (NDI) in high masticatory force areas, especially in molars. Implant splinting in cases of multiple missing teeth reduces lateral forces, improves force distribution, and minimizes stress on implants. However, no studies have evaluated the fatigue load resistance of unitary or splinted implants.

View Article and Find Full Text PDF

Statement Of The Problem: In most cases, insertion of single implants with a standard diameter is used to replace a molar tooth but placing two implants with a narrow diameter seems to be a viable treatment modality to withstand functional and biomechanical forces.

Purpose: This study aimed to evaluate and compare stress distribution in the bone surrounding a single molar area rehabilitated by a single implant versus two implants with a narrow diameter.

Materials And Method: The study was conducted by computer-aided modeling.

View Article and Find Full Text PDF

Background: Edentulous sites with limited horizontal tooth-implant distance pose a challenge to clinicians. This case report describes root amputation of an adjacent compromised molar to maintain an optimal tooth-implant distance METHODS AND RESULTS: A 41-year-old female was referred for extraction and implant placement to replace her left, maxillary second premolar (#13), which had been diagnosed with a vertical root fracture. Extraction and ridge preservation of #13 was completed without complication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!