Purpose: To determine the ideal position of a dental implant to assist a posterior extended partial removable dental prosthesis (PRDP), through stress values, displacement values, and deformation of periodontal ligament (PDL).

Materials And Methods: A finite element analysis of different implant positions was analyzed using a 3D mandible model from a human patient. Test models were created: model A (implant in second molar area), model B (implant in the first molar area), and model C (implant in premolar area). A control model without implant support was also created. Overall displacement values, von Mises stress distribution maps, and nonlinear deformations were evaluated.

Results: Some differences could be observed between test models. The introduction of an implant in the edentulous area, unlike a conventional removable partial denture without implant support, decreases stress values in the biological structures such as: mandible, tooth, soft tissue, and PDL. Placing the implant in the first molar area resulted in improved displacement values, and reduced maximum stress values at the peri-implant bone area, metal structure, and implant were observed.

Conclusions: Within the limitations of this study we can conclude that placing the implant in the position of the first molar improves biomechanical behavior of implant-assisted PRDPs.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.12722DOI Listing

Publication Analysis

Top Keywords

model implant
16
stress values
12
displacement values
12
molar area
12
implant
11
implant position
8
removable partial
8
partial denture
8
finite element
8
element analysis
8

Similar Publications

Metastasis represents a stage in which the therapeutic objective changes from curing disease to prolonging survival, as detection typically occurs at advanced stages. Technologies for the early identification of disease would enable treatment at a lower disease burden and heterogeneity. Herein, we investigate the vascular dynamics within a synthetic metastatic niche as a potential marker of disease progression.

View Article and Find Full Text PDF

Purpose: This study was performed to introduce, evaluate, and compare various novel assessment protocols designed for straightforward, reliable, and reproducible measurement of alveolar bone levels. These protocols are intended for standardized periodontal assessment and follow-up, utilizing cone-beam computed tomography (CBCT) images and manipulation of Digital Imaging and Communications in Medicine (DICOM) viewer software.

Materials And Methods: Two experienced oral and maxillofacial radiologists developed 5 distinct radiographic measurement protocols.

View Article and Find Full Text PDF

Risk factors for complications following volar locking plate fixation of distal radial fractures.

Orthop Traumatol Surg Res

December 2024

Service de Chirurgie Orthopédique et Traumatologique, Hôpital de la Cavale Blanche, Boulevard Tanguy Prigent, Brest 29200, France; Université de Bretagne Occidentale, UBO, Brest 29200, France; LaTIM, INSERM, UMR 1101, SFR IBSAM, Avenue Foch, Brest 29200, France. Electronic address:

Introduction: With the aging population comes an increase in the number of distal radial fractures and therefore in the number of cases requiring volar locking plate (VLP) fixation. The complication rates after VLP fixation vary greatly from one study to the next. Several authors have already focused on these complications and how to lower their rate.

View Article and Find Full Text PDF

Objectives: The objective of this study was to evaluate the long-term clinical outcomes of one-piece narrow-diameter implants (NDIs), with diameters of 2.5 mm and 3.0 mm, and to investigate the factors that affect marginal bone loss (MBL) around these implants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!