The aim of the study was to assess the mid-term effectiveness and safety of an original technique consisting of reconstructing fractures of the medial wall of the orbit with porous polyethylene implants with an exclusive transnasal approach. Twenty-five patients were treated. Each patient underwent a pre-operative ophthalmologic evaluation and a CT scan. The surgery started with an anteroposterior ethmoidectomy of the fractured side; all the fractured bone fragments were removed and all usual landmarks of healthy bony margins were identified. A Medpor sheet was placed endoscopically to reconstruct the fractured wall. Each patient received an immediate postoperative CT scan, and was evaluated at day 1, 7, 30 and 6 months after surgery clinically and with an endoscopic examination. In all patients, preoperative enophthalmos and/or diplopia were corrected. The CT scans showed excellent reconstruction of the fractured bony walls. The immediate postoperative period was characterized by a very high degree of subjective comfort. No perioperative complications were detected. At the 6 months follow up, all meshes appeared covered by epithelialized mucosa at the endoscopic inspection, and clinical results were stable. Scars or lid complications are always prevented. The technique described has become the standard to treat medial wall fractures in our department.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcms.2017.11.017 | DOI Listing |
BMC Oral Health
January 2025
Department of Prosthetic Dentistry, Biomaterials Division, Faculty of Dentistry, King Salman International University, El Tur, South Sinai, Egypt.
Purpose: Investigating high performance thermoplastic polymers as substitutes to titanium alloy, in fabrication of implants and attachments to support mandibular overdenture, aiming to overcome stress shielding effect of titanium alloy implants. AIM OF STUDY: Assessment of stress distribution in polymeric prosthetic components and bone around polymeric implants, in case of implant-supported mandibular overdenture.
Materials And Methods: 3D finite element model was established for mandibular overdenture, supported bilaterally by two implants at canine region, and retained by two ball attachments.
J Arthroplasty
January 2025
Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, California.
Introduction: The two-stage surgical protocols used for the treatment of periprosthetic joint infection (PJI) following total knee arthroplasty (TKA) are associated with marked patient morbidity. As such, alternatives such as durable "1.5-stage" spacer constructs have gained popularity.
View Article and Find Full Text PDFJ Endocrinol
January 2025
U Iwaniec, Skeletal Biology Laboratory, Oregon State University, Corvallis, United States.
Leptin increases focal inflammation and osteolysis induced by polyethylene particles in leptin-deficient ob/ob mice suggesting the adipokine, an important immune modulator, contributes to orthopedic implant failure. Focal inflammation leads to bone loss at distant skeletal sites, and it is plausible that leptin also contributes to this response. We tested this possibility in 6-week-old female ob/ob mice (6-8/group) by evaluating bone architecture, turnover, and gene expression 12 days following surgical placement of polyethylene particles over calvaria.
View Article and Find Full Text PDFJ Arthroplasty
January 2025
Oakland University William Beaumont School of Medicine, Rochester, MI; Department of Orthopedic Surgery, Corewell Health William Beaumont University Hospital, Royal Oak, MI. Electronic address:
Background: Hip instability following total hip arthroplasty (THA) is among the most common indications for revision surgery. The implantation of dual-mobility (DM) systems, designed to improve stability, continues to rise, and thus, characterizing in vivo implant damage modes is paramount.
Methods: Under an implant retrieval protocol, 51 DM THA systems were analyzed.
J Contemp Dent Pract
October 2024
Department of Crown and Bridge, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt.
Aim: To assess hard as well as soft peri-implant tissues within cases having two lost adjacent anterior teeth treated through placing either two implants with two separate crowns or only an implant along with a crown with a cantilever, and evaluating the effect of polyetheretherketone (PEEK) restoration on cantilever design up to 18 months after functional loading.
Materials And Methods: Twenty-seven participants (15 males and 12 females; mean age, 38.6 years; range 20-50 years) with missing two adjacent anterior teeth were treated with implant system (Flotecno implant system, Italy).