Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We describe an outbreak of associated with contaminated washing gloves, a commercially available Class I medical device. Triggered by an increase in complex (BCC) bacteremias and the detection of BCC in unopened packages of washing gloves, an ad hoc national outbreak committee comprising representatives of a public health organisation, a regulatory agency, and an expert association convened and commissioned an outbreak investigation. The investigation included retrospective case finding across Switzerland and whole genome sequencing (WGS) of isolates from cases and gloves. The investigation revealed that BCC were detected in clinical samples of 46 cases aged 17 to 91 years (33% females) from nine institutions between May 2015 and August 2016. Twenty-two isolates from case patients and 16 from washing gloves underwent WGS. All available outbreak isolates clustered within a span of < 19 differing alleles, while 13 unrelated clinical isolates differed by > 1,500 alleles. This BCC outbreak was rapidly identified, communicated, investigated and halted by an ad hoc collaboration of multiple stakeholders. WGS served as useful tool for confirming the source of the outbreak. This outbreak also highlights current regulatory limitations regarding Class I medical devices and the usefulness of a nationally coordinated outbreak response.