A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Dual-Butterfly Structure Gyroscope. | LitMetric

A Dual-Butterfly Structure Gyroscope.

Sensors (Basel)

College of Mechatronics Engineering and Automation, National University of Defense Technology, Changsha 410073, China.

Published: December 2017

This paper reports a dual-butterfly structure gyroscope based on the traditional butterfly structure. This novel structure is composed of two butterfly structures, each of which contains a main vibrational beam, four proof masses, and a coupling mechanism. The coupling mechanism in this proposed structure couples the two single butterfly structures and keeps the driving mode phases of the two single butterfly gyroscopes exactly opposite, increasing the double difference of traditional butterfly gyroscopes to a quad difference, which has the potential advantage of improving bias instability and g-sensitivity. The gyroscope was fabricated using a standard microfabrication method and tested in laboratory conditions. The experimental results show a Q-factor of 10,967 in driving mode and there were two peaks in the frequency responses curve of sensing direction due to unavoidable fabrication errors. Scale factor and bias instability were also measured, reaching a scale factor of 10.9 mV/°/s and a bias instability of 10.7°/h, according to the Allan Variance curve.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751678PMC
http://dx.doi.org/10.3390/s17122870DOI Listing

Publication Analysis

Top Keywords

bias instability
12
dual-butterfly structure
8
structure gyroscope
8
traditional butterfly
8
butterfly structures
8
coupling mechanism
8
single butterfly
8
driving mode
8
butterfly gyroscopes
8
scale factor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!