Background: Chronic benign neutropenia of infancy includes primary autoimmune neutropenia (pAIN) and chronic idiopathic neutropenia (CIN). A diagnosis of CIN is supported by the absence of free and/or cell-bound neutrophil autoantibodies, which can be detected by flow cytometry with the indirect-granulocyte immunofluorescence test (I-GIFT) and direct-granulocyte immunofluorescence test (D-GIFT), respectively. Conclusive evidence is lacking on the diagnostic value of the D-GIFT, whose performance requires specific laboratory expertise, may be logistically difficult, and hampered by very low neutrophil count in patient samples. This study investigated whether the evaluation of D-GIFT improves the diagnostic accuracy of pediatric neutropenia.

Procedure: I-GIFT and D-GIFT were performed in 174 pAIN, 162 CIN, 81 secondary AIN, 51 postinfection neutropenic, and 65 nonautoimmune neutropenic children referred to this laboratory during 2002-2014.

Results: Using 90% specific median fluorescence intensity cut-off values calculated by receiver operating characteristic curves, D-GIFT was positive in 49% of CIN patients, who showed similar clinical features as those with pAIN. In 44 (27%) of 162 CIN patients, I-GIFT was repeated two to three times in a year, resulting positive in 12 and two patients at second and third screening, respectively. Interestingly, 10 of the latter 14 patients showed a positive D-GIFT at the first serological screening. False positive D-GIFT was shown by 12% and 22% of nonneutropenic and nonautoimmune neutropenic patients, respectively.

Conclusions: D-GIFT evaluation improves the diagnostic accuracy of pediatric neutropenia, but improvement of cell-bound antibody detection is needed to decrease false positive results.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pbc.26904DOI Listing

Publication Analysis

Top Keywords

antibody detection
8
pediatric neutropenia
8
immunofluorescence test
8
d-gift
8
improves diagnostic
8
diagnostic accuracy
8
accuracy pediatric
8
162 cin
8
nonautoimmune neutropenic
8
cin patients
8

Similar Publications

Background: Helicobacter pylori bacteria colonize the gastric mucosa and contribute to the occurrence and development of gastrointestinal diseases. According to the WHO, H. pylori bacteria are considered class I carcinogen.

View Article and Find Full Text PDF

Multiple parameters define the treatment course with biologics for a psoriatic patient while treatment switches are often associated with worse prognosis. The purpose of this study was to describe the switching patterns of biologics for psoriasis in the Greek market landscape and to detect associated factors that may impact the evolvement of selected therapy. This is a retrospective cohort study using data recorded in the nationwide digital prescription database of Greece.

View Article and Find Full Text PDF

Background: Inadequate treatment of acute rejection (AR) in pediatric kidney transplant recipients (KTR) can contribute to early allograft failure. Serum creatinine is an insensitive marker of allograft function, especially in the pediatric population, and may not detect ongoing rejection after treatment. We evaluated the utility of follow-up biopsies to detect persistent inflammation and future episodes of rejection.

View Article and Find Full Text PDF

Background: Speckles tracking echocardiography imaging enables clinicians to detect subtle systolic dysfunction. The aim of the present study was to elucidate the differences in speckle tracking echocardiographic findings between immunoglobulin light chain amyloid cardiomyopathy (AL-CM) and transthyretin amyloid cardiomyopathy (TTR-CM).

Methods: The patients with a confirmed diagnosis of cardiac amyloidosis through cardiac biopsy from March 2013 to October 2022 were included.

View Article and Find Full Text PDF

Molecular imaging has significantly advanced the detection and analysis of in vivo metabolic processes, while single-modal techniques remain limited. Dual-modal imaging, particularly positron emission tomography (PET)-based combinations has emerged as a powerful solution, offering enhanced capabilities through integration with magnetic resonance imaging (MRI) or near-infrared fluorescence (NIRF) imaging. This review highlights recent progress in PET-based dual-modal imaging, focusing on the development of various bimodal probes derived from antibodies, nanoparticles, and peptides, and key applications including image-guided surgery and disease assessment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!