Aim: Hypoglycaemia in Type 1 diabetes is associated with mortality and morbidity, especially where awareness of hypoglycaemia is impaired. Clinical pathways for access to continuous glucose monitoring (CGM) and flash glucose monitoring technologies are unclear. We assessed the impact of CGM and flash glucose monitoring in a high-risk group of people with Type 1 diabetes.

Methods: A randomized, non-masked parallel group study was undertaken. Adults with Type 1 diabetes using a multiple-dose insulin-injection regimen with a Gold score of ≥ 4 or recent severe hypoglycaemia were recruited. Following 2 weeks of blinded CGM, they were randomly assigned to CGM (Dexcom G5) or flash glucose monitoring (Abbott Freestyle Libre) for 8 weeks. The primary outcome was the difference in time spent in hypoglycaemia (below 3.3 mmol/l) from baseline to endpoint with CGM versus flash glucose monitoring.

Results: Some 40 participants were randomized to CGM (n = 20) or flash glucose monitoring (n = 20). The participants (24 men, 16 women) had a median (IQR) age of 49.6 (37.5-63.5) years, duration of diabetes of 30.0 (21.0-36.5) years and HbA of 56 (48-63) mmol/mol [7.3 (6.5-7.8)%]. The baseline median percentage time < 3.3 mmol/l was 4.5% in the CGM group and 6.7% in the flash glucose monitoring. At the end-point the percentage time < 3.3 mmol/l was 2.4%, and 6.8% respectively (median between group difference -4.3%, P = 0.006). Time spent in hypoglycaemia at all thresholds, and hypoglycaemia fear, were different between groups, favouring CGM.

Conclusion: CGM more effectively reduces time spent in hypoglycaemia in people with Type 1 diabetes and impaired awareness of hypoglycaemia compared with flash glucose monitoring. (Clinical Trial Registry No: NCT03028220).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5888121PMC
http://dx.doi.org/10.1111/dme.13561DOI Listing

Publication Analysis

Top Keywords

glucose monitoring
36
flash glucose
32
type diabetes
16
people type
12
awareness hypoglycaemia
12
cgm flash
12
time spent
12
spent hypoglycaemia
12
glucose
10
monitoring
9

Similar Publications

Levilactobacillus brevis YT108, identified for its ability to metabolize prebiotic xylo-oligosaccharides (XOS), emerges as a candidate for probiotic use in synbiotic food formulations. This study aimed to investigate the metabolic and genomic traits associated with XOS metabolism in YT108 and to assess its probiotic attributes through whole genome sequencing and in vitro assays. Strain YT108 exhibited robust growth kinetics on XOS as the sole carbon source, with a growth profile comparable to that on glucose, achieving a pH reduction to 4.

View Article and Find Full Text PDF

Background: Reduced insulin secretion is linked to diabetes and cardiovascular disease (CVD), but its role in non-diabetic CVD patients is unclear. The homeostasis model assessment of β-cell function (HOMA-β) measures pancreatic β-cell function. This study investigated the association between HOMA-β and adverse cardiovascular events in non-diabetic CVD patients.

View Article and Find Full Text PDF

A stretchable, adhesive, and wearable hydrogel-based patches based on a bilayer PVA composite for online monitoring of sweat by artificial intelligence-assisted smartphones.

Talanta

January 2025

Department of Materials Science and Engineering, Sharif University of Technology, Azadi Avenue, Tehran, 14588-89694, Iran; Center for Bioscience and Technology, Institute for Convergence Science and Technology, Sharif University of Technology, Tehran, 14588-89694, Iran; Fraunhofer Institute for Manufacturing Technology and Advanced Materials, 28359, Bremen, Germany. Electronic address:

Real-time monitoring of sweat using wearable devices faces challenges such as limited adhesion, mechanical flexibility, and accurate detection. In this work, we present a stretchable, adhesive, bilayer hydrogel-based patch designed for continuous monitoring of sweat pH and glucose levels using AI-assisted smartphones. The patch is composed of a bottom PVA hydrogel layer functionalized with colorimetric reagents and glucose oxidase enzyme, while the top PVA-sucrose layer enhances skin adhesion and protects against air moisture.

View Article and Find Full Text PDF

In the modern age, half of the population is facing various chronic illnesses due to glucose maintenance in the body, major causes of fatality and inefficiency. The early identification of glucose plays a crucial role in medical treatment and the food industry, particularly in diabetes diagnosis. In the past few years, non-enzymatic electrochemical glucose sensors have received a lot of interest for their ability to identify glucose levels accurately.

View Article and Find Full Text PDF

This study presents an innovative glucose detection platform, featuring a highly sensitive, non-enzymatic glucose sensor. The sensor integrates nickel nanowires and a graphene thin film deposited on the gate region of an extended-gate electric double-layer field-effect transistor (EGEDL-FET). This unique combination of materials and device structure enables superior glucose sensing performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!