Prognostic Significance of Blood Pressure Variability on Beat-to-Beat Monitoring After Transient Ischemic Attack and Stroke.

Stroke

From the Department of Clinical Neurosciences, Centre for Prevention of Stroke and Dementia, University of Oxford, United Kingdom.

Published: January 2018

Background And Purpose: Visit-to-visit and day-to-day blood pressure (BP) variability (BPV) predict an increased risk of cardiovascular events but only reflect 1 form of BPV. Beat-to-beat BPV can be rapidly assessed and might also be predictive.

Methods: In consecutive patients within 6 weeks of transient ischemic attack or nondisabling stroke (Oxford Vascular Study), BPV (coefficient of variation) was measured beat-to-beat for 5 minutes (Finometer), day-to-day for 1 week on home monitoring (3 readings, 3× daily), and on awake ambulatory BP monitoring. BPV after 1-month standard treatment was related (Cox proportional hazards) to recurrent stroke and cardiovascular events for 2 to 5 years, adjusted for mean systolic BP.

Results: Among 520 patients, 26 had inadequate beat-to-beat recordings, and 22 patients were in atrial fibrillation. Four hundred five patients had all forms of monitoring. Beat-to-beat BPV predicted recurrent stroke and cardiovascular events independently of mean systolic BP (hazard ratio per group SD, stroke: 1.47 [1.12-1.91]; =0.005; cardiovascular events: 1.41 [1.08-1.83]; =0.01), including after adjustment for age and sex (stroke: 1.47 [1.12-1.92]; =0.005) and all risk factors (1.40 [1.00-1.94]; =0.047). Day-to-day BPV was less strongly associated with stroke (adjusted hazard ratio, 1.29 [0.97-1.71]; =0.08) but similarly with cardiovascular events (1.41 [1.09-1.83]; =0.009). BPV on awake ambulatory BP monitoring was nonpredictive (stroke: 0.89 [0.59-1.35]; =0.59; cardiovascular events: 1.08 [0.77-1.52]; =0.65). Despite a weak correlation (=0.119; =0.02), beat-to-beat BPV was associated with risk of recurrent stroke independently of day-to-day BPV (1.41 [1.05-1.90]; =0.02).

Conclusions: Beat-to-beat BPV predicted recurrent stroke and cardiovascular events, independently of mean systolic BP and risk factors but short-term BPV on ambulatory BP monitoring did not. Beat-to-beat BPV may be a useful additional marker of cardiovascular risk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5742536PMC
http://dx.doi.org/10.1161/STROKEAHA.117.019107DOI Listing

Publication Analysis

Top Keywords

cardiovascular events
28
beat-to-beat bpv
20
recurrent stroke
16
bpv
13
ambulatory monitoring
12
stroke cardiovascular
12
stroke
10
blood pressure
8
pressure variability
8
beat-to-beat
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!