Many methods exist for examining CpG DNA methylation. However, many of these are qualitative, laborious to apply to a large number of genes simultaneously, or are not easy to target to specific regions of interest. Microdroplet PCR-based bisulfite sequencing allows for quantitative single base resolution analysis of investigator selected regions of interest. Following bisulfite conversion of genomic DNA, targeted microdroplet PCR is conducted with custom primer libraries. Samples are then fragmented, concatenated, and sequenced by high-throughput sequencing. The most recent technology allows for this method to be conducted with as little as 250 ng of bisulfite-converted DNA. The primary advantage of this method is the ability to hand-select the targeted regions covered by up to 10,000 amplicons of 500-600 bp. Moreover, the nature of microdroplet PCR virtually eliminates PCR bias and allows for the amplification of all targets simultaneously in a single tube.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/978-1-4939-7481-8_17 | DOI Listing |
Diagn Microbiol Infect Dis
September 2024
Laboratory of Clinical, The Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Yanjiangxi Road, Guangzhou, Guangdong 510120, China. Electronic address:
Background: Infection with Neisseria gonorrhoeae in adults usually leads to vaginitis and acute urethritis, and infection through the birth canal in newborns can lead to acute neonatal conjunctivitis. In view of certain factors such as a high missed detection rate of N.gonorrhoeae from staining microscopy method, the time-consuming nature and limited sensitivity of bacterial culture method, complicated and inability of absolute quantification from the ordinary PCR method.
View Article and Find Full Text PDFACS Appl Bio Mater
May 2024
Department of Chemical Engineering and Applied Chemistry, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
Digital PCR (dPCR) has become indispensable in nucleic acid (NA) detection across various fields, including viral diagnostics and mutant detection. However, misclassification of partitions in dPCR can significantly impact accuracy. Despite existing methods to minimize misclassification bias, accurate classification remains elusive, especially for nonamplified target partitions.
View Article and Find Full Text PDFMicromachines (Basel)
December 2023
School of Physics, Changchun University of Science and Technology, Changchun 130022, China.
Digital polymerase chain reaction (PCR) technology in microfluidic systems often results in bubble formation post-amplification, leading to microdroplet fragmentation and compromised detection accuracy. To solve this issue, this study introduces a method based on the constant pressure regulation of microdroplets during PCR within microfluidic chips. An ideal pressure reference value for continuous pressure control was produced by examining air solubility in water at various pressures and temperatures as well as modeling air saturation solubility against pressure for various temperature scenarios.
View Article and Find Full Text PDFAnal Chem
February 2024
National Engineering Research Center for Optical Instruments, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310052, China.
Detecting proteins in ultralow concentrations in complex media is important for many applications but often relies on complicated techniques. Herein, a single-molecule protein analyzer with the potential for high-throughput applications is reported. Gold-coated magnetic nanoparticles with DNA-labeled antibodies were used for target recognition and separation.
View Article and Find Full Text PDFBiosensors (Basel)
September 2023
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
Uniform and stable droplet generation is critical for accurate and efficient digital nucleic acid analysis (dNAA). In this study, an integrated microfluidic step emulsification device with wide-range droplet generation capability, small device dimensions, convenient fabrication strategy, low contamination and high robustness was developed. A tree-shaped droplet generation nozzle distribution design was proposed to increase the uniformity of droplet generation by equating flow rates, and the flow field in the design was numerically simulated.