Objectives: To investigate the impact of an adaptive detector collimation on the dose parameters and accurateness of scan length adaption at prospectively ECG-triggered sequential cardiac CT with a wide-detector third-generation dual-source CT.
Methods: Ideal scan lengths for human hearts were retrospectively derived from 103 triple-rule-out examinations. These measures were entered into the new scanner operated in prospectively ECG-triggered sequential cardiac scan mode with three different detector settings: (1) adaptive collimation, (2) fixed 64 × 0.6-mm collimation, and (3) fixed 96 × 0.6-mm collimation. Differences in effective scan length and deviation from the ideal scan length and dose parameters (CTDIvol, DLP) were documented.
Results: The ideal cardiac scan length could be matched by the adaptive collimation in every case while the mean scanned length was longer by 15.4% with the 64 × 0.6 mm and by 27.2% with the fixed 96 × 0.6-mm collimation. While the DLP was almost identical between the adaptive and the 64 × 0.6-mm collimation (83 vs. 89 mGycm at 120 kV), it was 62.7% higher with the 96 × 0.6-mm collimation (135 mGycm), p < 0.001.
Conclusion: The adaptive detector collimation for prospectively ECG-triggered sequential acquisition allows for adjusting the scan length as accurate as this can only be achieved with a spiral acquisition. This technique allows keeping patient exposure low where patient dose would significantly increase with the traditional step-and-shoot mode.
Key Points: • Adaptive detector collimation allows keeping patient exposure low in cardiac CT. • With novel detectors the desired scan length can be accurately matched. • Differences in detector settings may cause 62.7% of excessive dose.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-017-5177-1 | DOI Listing |
J Clin Med
January 2025
Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok 10400, Thailand.
Injuries involving the Atlas (C1) and Axis (C2) vertebrae of the cervical spine present significant clinical challenges due to their complex anatomy and potential for severe neurological impairment. Traditional imaging methods often lack the detailed visualization required for precise surgical planning. This study aimed to develop high-resolution 3D models of the C1 and C2 vertebrae to perform a comprehensive morphometric analysis, identify gender differences, and assess bilateral symmetry to enhance surgical accuracy.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China.
Defects can be introduced into shotcrete materials after a few freeze-thaw cycles, which has a significant influence on the fracture performance of shotcrete. In this study, a series of shotcrete specimens with varying sizes, geometries, and initial crack lengths were prepared to investigate the fracture properties of notched shotcrete under freeze-thaw conditions. Considering the effects of specimen boundaries and material microstructure, a linear closed-form solution was proposed to determine the fracture toughness of frost-damaged shotcrete.
View Article and Find Full Text PDFIndian J Nucl Med
November 2024
Department of Nuclear Medicine and Molecular Imaging, Homi Bhabha Cancer Hospital & Mahamana Pandit Madan Mohan Malaviya Cancer Centre, Tata Memorial Centre, Homi Bhabha National Institute (HBNI), Varanasi, India.
Background: The introduction of positron emission tomography/computed tomography (PET/CT) has significantly advanced medical imaging. In oncology, F-fluorodeoxyglucose (F-FDG) PET/CT is particularly crucial for staging, evaluating treatment response, monitoring follow-up, and planning radiotherapy. However, in resource limiting hospitals, the availability of fluorine-labeled F-FDG limits optimal scan acquisition.
View Article and Find Full Text PDFJ Biomech
November 2024
Department of Orthopedics and Rehabilitation, The University of Iowa, United States; Department of Biomedical Engineering, The University of Iowa, United States; Department of Industrial and Systems Engineering, The University of Iowa, United States.
A CT-based method for objectively assessing fracture severity was previously developed and validated to address poor reliability in existing subjective fracture classification systems. The method involved quantifying the energy involved in creating a fracture. However, clinical utility of the method was hindered by reliance upon an intact contralateral CT and lengthy analysis time (8-10 h).
View Article and Find Full Text PDFNeuroradiology
January 2025
Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
Introduction: This study investigates the influence of carotid artery elongation on neurovascular intervention and outcome in acute stroke treatments proposing an easily assessable imaging marker for carotid elongation.
Methods: 118 patients who underwent mechanical thrombectomy for middle cerebral artery occlusions were included. The carotid elongation ratio (CER), center-line artery length to scan's Z-axis, was measured on the affected side in CT-angiographies.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!