A combination of antiretroviral agents is frequently used in effective treatment of the human immunodeficiency virus infection. In this study, two different separation methods are presented for the simultaneous determination of emtricitabine, rilpivirine and tenofovir from raw materials and urine samples. Developed liquid chromatography and capillary electrophoresis methods were thoroughly optimized for high analytical performances. Optimization of multiple variables at the same time by performing a minimum number of experiments was achieved by the Box-Behnken design, which is an experimental design in response surface methodology, in capillary electrophoresis. The results of the experimental design ensure minimum analysis time with well-separated analytes. Separation conditions, such as different stationary phases, pH level, organic modifiers and temperatures in liquid chromatography method, were also optimized. In particular, among stationary phases, the core-shell column especially enhanced the effectiveness of separation in liquid chromatography. Both methods were fully validated and applied to real samples. The main advantage of the developed methods is the separation of the drug combination in a short time with high efficiency and without any time-consuming steps.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.4158DOI Listing

Publication Analysis

Top Keywords

liquid chromatography
12
simultaneous determination
8
emtricitabine rilpivirine
8
rilpivirine tenofovir
8
capillary electrophoresis
8
experimental design
8
stationary phases
8
methods
5
determination validation
4
validation emtricitabine
4

Similar Publications

Drug-Drug Interaction Between Rifampicin and Albuvirtide: A Phase 1, Randomized, Open-Label Study.

J Clin Pharmacol

January 2025

Department of Pharmacy, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China.

Albuvirtide (ABT) is a novel long-acting fusion inhibitor for human immunodeficiency virus type 1 (HIV-1), and may be co-administered with rifampicin (RIF) in patients concurrent with tubercle bacillus and HIV-1. This study was conducted to investigate the pharmacokinetic effect of co-administration of the two drugs. In the study, 24 healthy volunteers were randomized to receive ABT alone or with RIF.

View Article and Find Full Text PDF

Mid-infrared spectra of dried and roasted cocoa ( L.): A dataset for machine learning-based classification of cocoa varieties and prediction of theobromine and caffeine content.

Data Brief

February 2025

Centro Surcolombiano de Investigación en Café (CESURCAFÉ), Departamento de Ingeniería Agrícola, Universidad Surcolombiana, Neiva-Huila 410001, Colombia.

This paper presents a comprehensive dataset of mid-infrared spectra for dried and roasted cocoa beans ( L.), along with their corresponding theobromine and caffeine content. Infrared data were acquired using Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) spectroscopy, while High-Performance Liquid Chromatography (HPLC) was employed to accurately quantify theobromine and caffeine in the dried cocoa beans.

View Article and Find Full Text PDF

Background: Due to its exceptional effectiveness, clozapine (CLO), whose metabolite is norclozapine (NCLO), is a drug of choice in the management of treatment-resistant schizophrenia. The purpose of this study was to assess the factors modifying the CLO/NCLO ratio (CNR).

Methods: A total of 446 blood samples (233 of which were drawn from females and 213 from males, aged from 18 to 77 years) were analyzed in this study.

View Article and Find Full Text PDF

Diabetes is a metabolic disorder caused by the body's inability to produce or use insulin. Considering the figures projected by the World Health Organization, research on insulin therapy is crucial. Hence, we present a soft biointerface based on a thiol-yne poly(ethylene glycol) (PEG) click-hydrogel as an advanced treatment option to administrate insulin.

View Article and Find Full Text PDF