A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Endoscopic sentinel lymph node biopsy using indocyanine green-neomannosyl human serum albumin. | LitMetric

Objective: The aim of this study was to determine the possibility of endoscopic sentinel lymph node biopsy of the head and neck region using indocyanine green-neomannosyl human serum albumin (ICG:MSA) and a custom-made intraoperative color-and-fluorescence-merged imaging system (ICFIS).

Methods: Using mouse and rabbit models of tongue cancer, we performed sentinel lymph node biopsy using an ICG:MSA tracer and custom imaging system equipped with an endoscope.

Results: ICG:MSA was localized to the cervical lymph node on the ipsilateral side for up to 30 minutes compared to ICG tracer (ICG n = 3, IGC:MSA n = 3). Detection of sentinel lymph nodes was attempted after injecting ICG:MSA in the mouse tongue cancer model (n = 3). During the operation, lymph nodes were easily identified and resected using ICFIS without the aid of other magnifiers. In the rabbit tongue cancer model (n = 3), the ICFIS equipped with 30-degree endoscopy was used to confirm the feasibility of endoscopic sentinel lymph node biopsy. The entire sentinel lymph node biopsy procedure was performed using the ICFIS with the 30-degree endoscope. We detected and dissected sentinel lymph nodes in the rabbit model without the other sentinel lymph node detection tools.

Conclusion: We confirmed the usefulness of sentinel lymph node biopsy using a near infrared fluorescence technique and endoscopic system. Avoidance of radiation exposure and shine-through phenomena, which are problems of sentinel lymph node biopsy using conventional radioisotopes, are advantages of our surgical technique. By combining the endoscopic system with a sentinel lymph node biopsy procedure, we avoided visible neck scars, which lead to excellent cosmetic outcomes.

Level Of Evidence: NA. Laryngoscope, 128:E135-E140, 2018.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lary.27036DOI Listing

Publication Analysis

Top Keywords

sentinel lymph
44
lymph node
40
node biopsy
32
lymph
13
endoscopic sentinel
12
tongue cancer
12
lymph nodes
12
node
10
sentinel
10
biopsy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!