  • Catheter-related bloodstream infections (CRBSI) are serious complications for patients needing long-term vascular catheters, prompting the need for effective antimicrobial treatments.
  • Taurolidine, an antimicrobial agent, is the active component in Neutrolin®, a recently introduced catheter lock solution that has shown potential in preventing infections.
  • A study involving 201 patients over two years reported low CRBSI rates and no major side effects from Neutrolin®, suggesting its effectiveness when combined with proper catheter care.

Article Abstract

Catheter-related bloodstream infections (CRBSI) are major complications for patients with life-threatening conditions requiring chronic vascular catheterization. The wide range of etiologic microbes and the ongoing development of resistance to antimicrobials with specific mechanisms of action make this an appropriate target for applying a nonspecific antimicrobial therapeutic. Taurolidine hydrolyzes into two antimicrobial moieties, formaldehyde and methylene glycol, which react with microbial surfaces. Neutrolin® (taurolidine, heparin, calcium citrate) was recently introduced in Germany as an antimicrobial catheter lock solution. This postmarketing experience collected data on 201 patients at 20 centers from January 2014 through September 2016. Likely CRBSI was observed in 13 episodes in 47,118 days (0.2759 per 1000 days [0.1468, 0.4718]). Thrombosed catheter was observed in seven catheters in 47,118 days (0.1486 per 1000 days [0.0595, 0.3061]). No adverse drug reactions that led to the discontinuation of Neutrolin® use were reported. Two patients experienced occasional transient dysgeusia. Neutrolin®, when used in conjunction with guideline-based catheter care, showed reduction in the rate of both CRBSI and catheter thrombosis relative to recent historical controls.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5978892PMC
http://dx.doi.org/10.1007/s10096-017-3157-7DOI Listing

Publication Analysis

Top Keywords

postmarketing experience
8
neutrolin® taurolidine
8
taurolidine heparin
8
heparin calcium
8
calcium citrate
8
catheter lock
8
lock solution
8
catheter
5
neutrolin®
4
experience neutrolin®
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!