Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate B-mode ultrasound as a novel method for the examination of pupillary function and to provide normal values for the pupillary reflex as assessed by B-mode ultrasound.
Methods: 100 subjects (49 female, 51 male, mean [range] age 51 [18-80 years]) with no history of ophthalmologic disease, no clinically detectable pupillary defects, and corrected visual acuity ≥ 0.8 were included in this prospective observational study. B-mode ultrasound was performed with the subjects eyes closed using an Esaote-Mylab25 system according to current guidelines for orbital insonation. A standardized light stimulus was applied.
Results: The mean ± standard deviation left and right pupillary diameters (PD) at rest were 4.7 ± 0.8 and 4.5 ± 0.8 mm. Following an ipsilateral light stimulus (Lstim), left and right constricted PD were 2.8 ± 0.6 and 2.7 ± 0.6 mm. Following a contralateral Lstim, left and right constricted PD were 2.7 ± 0.6 and 2.6 ± 0.5 mm. Left and right pupillary constriction time (PCT) following ipsilateral Lstim were 970 ± 261.6 and 967 ± 220 ms. Left and right PCT following a contralateral Lstim were 993.8 ± 192.6 and 963 ± 189.4 ms. Patient age was inversely correlated with PD at rest and with PD after ipsilateral and contralateral Lstim (all p<0.001), but not with PCT.
Conclusions: B-mode ultrasound is a simple, rapid and objective method for the quantitative assessment of pupillary function, which may prove useful in a variety of settings where eyelid retraction is impeded or an infrared pupillometry device is unavailable.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5718517 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0189016 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!