Optimizing outcomes with toric intraocular lenses.

Indian J Ophthalmol

Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.

Published: December 2017

Toric intraocular lenses (IOLs) are the procedure of choice to correct corneal astigmatism of 1 D or more in cases undergoing cataract surgery. Comprehensive literature search was performed in MEDLINE using "toric intraocular lenses," "astigmatism," and "cataract surgery" as keywords. The outcomes after toric IOL implantation are influenced by numerous factors, right from the preoperative case selection and investigations to accurate intraoperative alignment and postoperative care. Enhanced accuracy of keratometry estimation may be achieved by taking multiple measurements and employing at least two separate devices based on different principles. The importance of posterior corneal curvature is increasingly being recognized in various studies, and newer investigative modalities that account for both the anterior and posterior corneal power are becoming the standard of care. An ideal IOL power calculation formula should take into account the surgically induced astigmatism, the posterior corneal curvature as well as the effective lens position. Conventional manual marking has given way to image-guided systems and intraoperative aberrometry, which provide a mark-less IOL alignment and also aid in planning the incisions, capsulorhexis size, and optimal IOL centration. Postoperative toric IOL misalignment is the major factor responsible for suboptimal visual outcomes after toric IOL implantation. Realignment of the toric IOL is needed in 0.65%-3.3% cases, with more than 10° of rotation from the target axis. Newer toric IOLs have enhanced rotational stability and provide precise visual outcomes with minimal higher order aberrations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5742958PMC
http://dx.doi.org/10.4103/ijo.IJO_810_17DOI Listing

Publication Analysis

Top Keywords

toric iol
16
outcomes toric
12
posterior corneal
12
toric intraocular
8
intraocular lenses
8
iol implantation
8
corneal curvature
8
visual outcomes
8
toric
7
iol
7

Similar Publications

Comparison of two strategies estimating surgically induced astigmatism in position prediction of toric IOLs in 2.2 mm cataract surgery.

Graefes Arch Clin Exp Ophthalmol

December 2024

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, No. 83 Fenyang Road, Shanghai, 200031, China.

Purpose: To compare the precision of the arithmetic mean of surgically induced astigmatism (M-SIA) and the centroid of surgically induced astigmatism (C-SIA) in estimating SIA when predicting the power and axis of toric IOLs under different circumstances.

Methods: 120 eyes of 99 patients undergoing toric IOL replacement in a simple cataract surgery were included in the retrospective study. The predicted position of toric IOL was calculated by Z Calc online calculator and Barrett Toric Calculator with M-SIA (0.

View Article and Find Full Text PDF

Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).

Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging.

View Article and Find Full Text PDF

Purpose: To explore the significance of changes in anterior chamber depth (ΔACD) and astigmatism between 4 and 8 weeks following uneventful phacoemulsification.

Patients And Methods: Anterior chamber depth (ACD, mm), autorefractometry and subjective refraction were monitored in pseudophakic eyes implanted with non-toric IOLs (group 1, SA60AT, n=36; group 2, SN60WF, n=34; group 3, ICBOO, n=16) and phakic control group (n=30, group 4a, for ACD and autorefractometry) over four weeks. Changes in subjective refractions were compared with repeatability in normal phakic eyes (n=30, group 4b).

View Article and Find Full Text PDF

Phacoemulsification and intraocular lens (IOL) implantation comprise a standard procedure for cataract treatment. However, minimal refractive error remains a determinant of postoperative results. Our study aimed to evaluate the refractive outcomes and the impact of the surgeon's experience and the IOL model on Kosovan and Hungarian patients after cataract surgery.

View Article and Find Full Text PDF

Purpose: Accurate alignment of Toric Intraocular Lens (T-IOLs) in cataract surgery is crucial for good visual outcomes. The purpose of this study was to evaluate the influence of rotation, axial shift and their combined effects on the refractive error and image quality of a wide range of T-IOL powers (from +1.50 D to +6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!