A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In-vitro comparison of mechanical resistance between two straight plates and a Y-plate for fixation of mandibular condyle fractures. | LitMetric

Objective: To compare the mechanical resistance of conventional plates with a modified Y-plate in mandibular condyle fracture.

Materials And Methods: 40 synthetic hemi-mandibular polyurethane replicates were used. Two groups of fixing materials were included: 20 mandibles fixed with 40 straight plates with four roles each (2.0 mm system) and 20 mandibles fixed with 20 Y-shaped plates (2.0 mm system and 1.5 mm thickness). The samples were submitted to linear loading in the following directions: 10 mandibles from each group from lateral to medial and 10 mandibles from each group from anterior to posterior. A universal loading machine, Instron Universal 4411, was used to performed the tests, and the resistance of each fixed mandible was assessed at displacements of 1 mm, 3 mm, and 5 mm. The t-test for independent samples was performed. The p value was set at <0.05.

Results: The worst mechanical resistance was found in the Y-plates loaded from anterior to posterior. The best mechanical resistance was in two straight hole plates loaded from lateral to medial. The Y-plates and two straight hole plates showed similar resistance when a lateral to medial load was applied.

Conclusion: There was no difference between the plates when lateral to medial loading was tested.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcms.2017.11.005DOI Listing

Publication Analysis

Top Keywords

mechanical resistance
8
straight plates
8
mandibular condyle
8
mandibles fixed
8
20 mm system
8
mandibles group
8
in-vitro comparison
4
comparison mechanical
4
resistance straight
4
plates
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!