A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of Cardiac Index and Extravascular Lung Water After Single-Lung Transplantation Using the Transpulmonary Thermodilution Technique by the PiCCO2 Device. | LitMetric

Objectives: First evaluation of the transpulmonary thermodilution technique by the PiCCO2 device to assess cardiac index and pulmonary edema during the postoperative course after single-lung transplantation.

Design: Prospective observational study.

Settings: Intensive care unit, university hospital (single center).

Participants: Single-lung transplant patients.

Interventions: The authors compared cardiac index measured by PiCCO2 and pulmonary artery catheter and assessed pulmonary edema using extravascular lung water index and pulmonary vascular permeability index measured by PiCCO2.

Measurements And Main Results: A Bland-Altman method was used to compare cardiac index measured by PiCCO2 and pulmonary artery catheter. Extravascular lung water index and pulmonary vascular permeability index were compared according to the PaO/FiO ratio with a threshold value of 150 mmHg. Ten single-lung transplant patients were included. Cardiac index measured by PiCCO2 and pulmonary artery catheter were 3.3 L/min/m (2.9-3.6) and 2.5 L/min/m (2.2-3.0). Bias for cardiac index was 0.71 L/min/m (-0.03; 1.44) and limit of agreements were -0.03 and 1.44 L/min/m. Extravascular lung water index was 12 mL/kg (11-16) and pulmonary vascular permeability index was 2.3 (2.0-3.1), consistent with pulmonary edema. Extravascular lung water index was higher in the group of PaO/FiO ratio ≤150 mmHg compared with the group of PaO/FiO ratio >150 mmHg (17 v 12 mL/kg, p = 0.04), whereas pulmonary vascular permeability index only tended to be higher (3.1 v 2.1, p = 0.06).

Conclusion: PiCCO2 device systematically overestimated cardiac index compared with pulmonary artery catheter. However, it might be useful to assess pulmonary edema in acute respiratory failure after single-lung transplantation.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2017.10.026DOI Listing

Publication Analysis

Top Keywords

extravascular lung
20
lung water
20
pulmonary edema
16
pulmonary artery
16
artery catheter
16
pulmonary vascular
16
vascular permeability
16
picco2 device
12
pulmonary
12
cardiac measured
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!