Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: Goal-directed fluid therapy (GDFT) based on pulse pressure variation (PPV) was used in anaesthetized dogs undergoing abdominal surgeries. The aims were 1) to evaluate the success rate of the PPV ≥13% in detecting fluid responsiveness [delta stroke volume (ΔSV) ≥10%]; 2) to assess the correlation between PPV, systolic pressure variation (SPV), Plethysmograph Variability Index (PVI) and central venous pressure (CVP) and 3) to establish the threshold value for the PVI that would predict a PPV value of ≥13% and indirectly discriminate responders from nonresponders to fluid therapy.
Study Design: Clinical, prospective, interventional study.
Animals: A total of 63 client-owned dogs scheduled for abdominal procedures.
Methods: PPV and SPV were calculated manually from the invasive blood pressure trace on the Datex monitor. PVI was recorded from the Masimo pulse oximeter. Fluid challenge (10 mL kg Compound Sodium Lactate) was performed when PPV was ≥13% and/or mean arterial pressure (MAP) < 60 mmHg. Fluid responsiveness was assessed by the transoesophageal Doppler probe. Cardiovascular parameters (heart rate, MAP, PPV, SPV, PVI, SV and if available, CVP) were measured before and after each fluid intervention.
Results: PPV ≥ 13% reliably predicted fluid responsiveness in 82.9% of cases. There was positive correlation between PPV and SPV (r = 0.84%), PPV and logPVI (r = 0.46) as well as SPV and logPVI (r = 0.45). Noninvasive PVI value ≥13% should predict PPV threshold value (13%) with 97% sensitivity and 68% specificity. There was no statistically significant correlation between PPV and CVP.
Conclusions: PPV is a useful clinical tool to detect occult hypovolaemia and predict cardiovascular response to fluid challenge. Use of PPV is recommended as a part of GDFT in dogs undergoing abdominal procedures.