Background: Many randomized controlled trials have been performed with the goal of improving outcomes related to hemodialysis vascular access. If the reported outcomes are relevant and measured consistently to allow comparison of interventions across trials, such trials can inform decision making. This study aimed to assess the scope and consistency of vascular access outcomes reported in contemporary hemodialysis trials.

Study Design: Systematic review.

Setting & Population: Adults requiring maintenance hemodialysis.

Selection Criteria: All randomized controlled trials and trial protocols reporting vascular access outcomes identified from ClinicalTrials.gov, Embase, MEDLINE, and the Cochrane Kidney and Transplant Specialized Register from January 2011 to June 2016.

Interventions: Any hemodialysis-related intervention.

Outcomes: The frequency and characteristics of vascular access outcome measures were analyzed and classified.

Results: From 168 relevant trials, 1,426 access-related outcome measures were extracted and classified into 23 different outcomes. The 3 most common outcomes were function (136 [81%] trials), infection (63 [38%]), and maturation (31 [18%]). Function was measured in 489 different ways, but most frequently reported as "mean access blood flow (mL/min)" (37 [27%] trials) and "number of thromboses" (30 [22%]). Infection was assessed in 136 different ways, with "number of access-related infections" being the most common measure. Maturation was assessed in 44 different ways at 15 different time points and most commonly characterized by vein diameter and blood flow. Patient-reported outcomes, including pain (19 [11%]) and quality of life (5 [3%]), were reported infrequently. Only a minority of trials used previously standardized outcome definitions.

Limitations: Restricted sampling frame for feasibility and focus on contemporary trials.

Conclusions: The reporting of access outcomes in hemodialysis trials is very heterogeneous, with limited patient-reported outcomes and infrequent use of standardized outcome measures. Efforts to standardize outcome reporting for vascular access are critical to optimizing the comparability, reliability, and value of trial evidence to improve outcomes for patients requiring hemodialysis.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.ajkd.2017.09.018DOI Listing

Publication Analysis

Top Keywords

vascular access
24
access outcomes
16
outcome measures
12
outcomes
11
trials
10
outcomes reported
8
hemodialysis trials
8
randomized controlled
8
controlled trials
8
outcomes hemodialysis
8

Similar Publications

Safety of accessing brachial veins for large-bore upper extremity venous thrombectomy using ClotTriever Thrombectomy System.

CVIR Endovasc

January 2025

Department of Radiology, Section of Vascular and Interventional Radiology, University of Washington, 1959 Northeast Pacific Street, Seattle, WA, 98195, USA.

Purpose: To evaluate access site adverse events following ClotTriever-mediated large-bore mechanical thrombectomy via small upper extremity deep veins (< 6-mm).

Materials And Methods: Twenty patients, including 24 upper extremity venous access sites, underwent ClotTriever-mediated large-bore thrombectomy of the upper extremity and thoracic central veins for symptomatic deep vein obstruction unresponsive to anticoagulation. Patients without follow-up venous duplex examinations (n = 3) were excluded.

View Article and Find Full Text PDF

Background: This study aimed to clarify the appropriate timing for epinephrine administration in adults with out-of-hospital cardiac arrest (OHCA), particularly those cases with nonshockable rhythms, by addressing resuscitation time bias.

Methods: We performed a retrospective observational study utilizing a multicenter OHCA registry involving 95 hospitals in Japan between June 2014 and December 2020. We included patients with OHCA and nonshockable rhythms who received epinephrine during resuscitation.

View Article and Find Full Text PDF

: The safety and efficacy of electrophysiological (EP) procedures using ultrasound (US) guidance are being increasingly studied. We investigated if a systematic workflow with ultrasound guidance (the US4ABL), comprising four steps (transesophageal echocardiography (TEE) for left atrial thrombus exclusion, US of the groin vessels to guide femoral access, TEE-aided transseptal puncture, and transthoracic echocardiography (TTE) for exclusion of pericardial tamponade after the procedure), reduces the number of complications and fluoroscopy duration and dose. : A total of 212 consecutive patients underwent left-sided ablations using the US4ABL workflow and were compared to a group of 299 patients who underwent the same type of ablations using post-procedural TTE to exclude tamponade (standard group: venous and/or arterial access by palpation and fluoroscopy, and pressure guided transseptal puncture).

View Article and Find Full Text PDF

: A Peripherally Inserted Central Catheter (PICC) is a safe and effective Central Vascular Access Device when properly used. Therefore, it has become an increasingly frequent procedure. Nurses are often the professionals responsible for its insertion, maintenance, and removal.

View Article and Find Full Text PDF