Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
[Purpose] The purpose of this study is to investigate the effect of the newly designed multi joint ankle-foot orthosis on the gait and dynamic balance of stroke patients having foot drop. [Subjects and Methods] This study was conducted with 15 subjects who were diagnosed with stroke. 10-meter walk test, functional reaching test and timed up and go test were measured after each subjects wore a plastic ankle-foot orthosis and a multi joint ankle-foot orthosis that consists of orthosis joints (having free joint, anterior-stop joint, poster-stop joint, and Klenzak joint functions). In the case of the newly developed multi joint ankle-foot orthosis, the experiments were performed using posterior-stop joint and Klenzak joint. [Results] 10-meter walk test, functional reaching test and timed up and go test showed significant differences in the orthosis using posterior joint-stop function and Klenzak joint function. [Conclusion] The appropriate use of the four functions of the newly designed multi joint ankle-foot orthosis is expected to have a positive effect on improving the gait and balancing ability of stroke patients having foot drop.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5702809 | PMC |
http://dx.doi.org/10.1589/jpts.29. | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!