A New Design for Maximum Conformity of Total Knee Prosthesis to Femur and Tibia.

J Long Term Eff Med Implants

Department of Orthopedics and Traumatology, Faculty of Medicine, Atatürk University, Erzurum, Turkey 25240.

Published: January 2016

Total knee arthroplasty (TKA) is a common procedure for treating patients with excessively arthritic knees. Nonetheless, early failure of TKA may occur in the first 5 yr, and up to 20% of TKA procedures can fail after 20 yr. In this study, a new anatomic prosthesis was designed to provide maximum conformity to knee bones and produce less stress and strain, in an effort to avoid possible failure of the prosthesis. Anatomical and conventional knee models were compared on the basis of both geometric conformity and stress and strain results obtained from finite element analysis. To compare geometric conformity, anatomic prosthesis components were manufactured by laser melting, and conventional prosthesis components were fixed to sawbone knee models. The anatomical model yielded up to 50% less contact pressure at the insert, which may indicate potential for reduced wear between insert and femur components. This model also resulted in less principal strain value at the tibial component, considered to be an important parameter to indicate loosening. The anatomical model with a new femur component in the anterior cortex design also yielded less stress at the femoral cortex, when compared to the conventional model. The findings in this study suggest that the anatomic prosthesis model may be a better design alternative to conventional knee prostheses in terms of wear, aseptic loosening, and normal joint biomechanics.

Download full-text PDF

Source
http://dx.doi.org/10.1615/JLongTermEffMedImplants.2017020207DOI Listing

Publication Analysis

Top Keywords

anatomic prosthesis
12
maximum conformity
8
total knee
8
study anatomic
8
stress strain
8
conventional knee
8
knee models
8
geometric conformity
8
prosthesis components
8
anatomical model
8

Similar Publications

This prospective, observational cohort study compares the clinical and radiographic outcomes of the modified Weaver and Dunn (WD) technique with the newer, anatomical double-button plus tendon allograft technique (DB), and the suture anchor repair plus tendon allograft (SA). The study cohort includes 53 patients, who underwent surgery for acromioclavicular joint (ACJ) dislocation Rockwood type 3, 4 and 5. Patient-reported outcome scores and clinical results, including Disabilities of the Arm, Shoulder and Hand (DASH), the Subjective Shoulder Value (SSV), the Visual Analogue Scale (VAS) and the Constant score (CS) results as well as loss of reduction rates on plain radiographs were compared.

View Article and Find Full Text PDF

Sandwiched Strut Allografts with Stem Retention to Treat Fragile Periprosthetic Femoral Fractures: A Case Report.

Medicina (Kaunas)

January 2025

Department of Orthopaedic Surgery, Chosun University Hospital, 365 Pilmundae-ro, Dong-gu, Gwangju 61453, Republic of Korea.

Managing periprosthetic femoral fractures is challenging, particularly in osteoporotic patients with fragile bones. Revision with a long stem is commonly considered but may fail to provide adequate fixation and stability in fragile bones. A novel approach using sandwiched strut allografts and controlled bone crushing with robust cable fixation can offer mechanical support and provide secondary stability to the loosened femoral stem and can be considered a treatment option for low-demand patients.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

A basicervical femoral fracture is a relatively uncommon type of proximal femoral fracture. However, as the proportion of proximal femoral fractures rises in conjunction with the aging of society, the absolute number of patients with basicervical femoral fractures is also increasing. Nevertheless, the optimal surgical methods for the treatment of basicervical femoral fractures remain a topic of debate.

View Article and Find Full Text PDF

[Application of dual chamber round tissue expander in immediate breast reconstruction].

Beijing Da Xue Xue Bao Yi Xue Ban

February 2025

Department of Plastic Surgery, Peking University Third Hospital, Beijing 100191, China.

Objective: To explore the application value of dual chamber round tissue expander in immediate breast reconstruction.

Methods: Sixteen patients, who had been provided immediate tissue expander/implant two-stage breast reconstruction using dual chamber round tissue expander in our hospital from March 2022 to October 2023, were involved in this study, and the relevant information was analyzed retrospectively. The overall design of the expander is a round shape, consisting of two equally divided semi-circular chambers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!