Can pulpal floor debonding be detected from occlusal surface displacement in composite restorations?

Dent Mater

Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, USA. Electronic address:

Published: January 2018

Objectives: Polymerization shrinkage of resin composite restorations can cause debonding at the tooth-restoration interface. Theory based on the mechanics of materials predicts that debonding at the pulpal floor would half the shrinkage displacement at the occlusal surface. The aim of this study is to test this theory and to examine the possibility of detecting subsurface resin composite restoration debonding by measuring the superficial shrinkage displacements.

Methods: A commercial dental resin composite with linear shrinkage strain of 0.8% was used to restore 2 groups of 5 model Class-II cavities (8-mm long, 4-mm wide and 4-mm deep) in aluminum blocks (8-mm thick, 10-mm wide and 14-mm tall). Group I had the restorations bonded to all cavity surfaces, while Group II had the restorations not bonded to the cavity floor to simulate debonding. One of the proximal surfaces of each specimen was sprayed with fine carbon powder to allow surface displacement measurement by Digital Image Correlation. Images of the speckled surface were taken before and after cure for displacement calculation. The experiment was simulated using finite element analysis (FEA) for comparison.

Results: Group I showed a maximum occlusal displacement of 34.7±6.7μm and a center of contraction (COC) near the pulpal floor. Group II had a COC coinciding with the geometric center and showed a maximum occlusal displacement of 17.4±3.8μm. The difference between the two groups was statistically significant (p-value=0.0007). Similar results were obtained by FEA. The theoretical shrinkage displacement was 44.6 and 22.3μm for Group I and II, respectively. The lower experimental displacements were probably caused by slumping of the resin composite before cure and deformation of the adhesive layer.

Significance: The results confirmed that the occlusal shrinkage displacement of a resin composite restoration was reduced significantly by pulpal floor debonding. Recent in vitro studies seem to indicate that this reduction in shrinkage displacement could be detected by using the most accurate intraoral scanners currently available. Thus, subject to clinical validation, the occlusal displacement of a resin composite restoration may be used to assess its interfacial integrity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2017.11.019DOI Listing

Publication Analysis

Top Keywords

resin composite
24
pulpal floor
16
shrinkage displacement
16
composite restoration
12
occlusal displacement
12
displacement
10
floor debonding
8
occlusal surface
8
surface displacement
8
group restorations
8

Similar Publications

Light-curing of restorative composite through milled and 3D-printed full-contour zirconia for adhesive luting.

Dent Mater

January 2025

KU Leuven, Department of Oral Health Sciences, BIOMAT & UZ Leuven, Dentistry, Kapucijnenvoer 7, 3000 Leuven, Belgium. Electronic address:

Objectives: To evaluate the effect of different zirconia compositions and manufacturing processes on the light irradiance (LI), to measure the degree of conversion (DC) of solely light-curing restorative composite underneath these zirconia grades and to evaluate the respective zirconia microstructures.

Methods: Six dental zirconia grades (GC HT, GC UHT [GC]; Katana HT, Katana UTML [Kuraray Noritake]; Lava Esthetic, Lava Plus [3 M Oral Care]) were cut and sintered per manufacturer instructions. One 3D-printed zirconia grade (XJet [XJET]) was prepared according to previous research.

View Article and Find Full Text PDF

Experimental investigation and finite element analysis on the durability of root-filled teeth treated with multisonic irrigation.

Dent Mater

January 2025

Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, USA. Electronic address:

Objective: This study compared the fracture load, stress distribution, and survival probability under cyclic loading of extensively restored teeth treated with multisonic irrigation with those treated with conventional instrumentation, with or without a post.

Methods: Mesial-occlusal-distal cavities were prepared in 30 human mandibular premolars. The teeth were randomly divided into 3 groups of 10 based on the endodontic and restorative procedures: (1) Root canal treatment (RCT) followed by resin composite restoration (control group), (2) RCT followed by a glass fiber post restoration (conventional group), and (3) minimal instrumentation plus multisonic irrigation followed by resin composite restoration (GW group).

View Article and Find Full Text PDF

Objective:  Continuous advancements in composite resin materials have revolutionized and expanded its clinical use, improving its physical and mechanical properties. Attaining and retaining surface texture and gloss are crucial for the long-term durability of the composite resin material. This study investigated the supra-nanospherical filler composite material compared with different composite resin materials immersed in different beverages.

View Article and Find Full Text PDF

Background: The fracture of an endodontic instrument within the root canal system can occur during root canal therapy, complicating thorough cleaning and shaping. Consequently, managing the broken fragment becomes crucial.

Methods: Eighty Nickel-titanium (NiTi) #20 K-files (Mani, Tochigi, Japan) were cut 8 mm from the tip, fixed into a corkboard, and classified into five groups (n = 14 each).

View Article and Find Full Text PDF

The quest for an esthetically pleasing smile is a key driver in seeking dental interventions aimed at achieving a more balanced and harmonious appearance. The purpose of this report is to discuss the restoration of conical lateral incisors in an 11-year-old patient. The treatment approach employed direct composite resin restorations associated with the Digital Smile Design (DSD) technology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!