A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of a radial neck notch on press-fit stem stability: a biomechanical study on 7 cadavers. | LitMetric

The effect of a radial neck notch on press-fit stem stability: a biomechanical study on 7 cadavers.

J Shoulder Elbow Surg

Biomechanics Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA. Electronic address:

Published: March 2018

Background: Minimal micromotion is necessary for osteointegration of cementless radial head prostheses. When radial head fractures extend longitudinally, where the neck cut for prosthetic replacement should be made is uncertain. We hypothesized that complete resection of the notched portion of a radial neck confers no advantage in initial stability compared with not resecting the defect and inserting the implant into a notched radial neck.

Materials And Methods: The radii of 7 cadavers underwent radial head resection and implantation with a 25-mm-long press-fit radial head stem. Before implantation, a 5-mm-long notch that was less than 1-mm wide was made in the radial neck. After the stem-bone micromotion was recorded, the proximal 5 mm of radial neck, incorporating the entire notch, was cut away, the stem was inserted 5 mm further, and the resulting micromotion was recorded.

Results: The mean micromotion measured in the presence of a cortical notch was 51 ± 6 µm. After the neck was circumferentially cut and the stem was advanced, the micromotion (46 ± 9 µm) was not statistically significantly different.

Discussion: Initial stability of an adequately sized cementless stem in the presence of a 5-mm-long cortical notch was well within the threshold needed for bone ingrowth (<100 µm). In addition, there was no reduction of micromotion after the notch-containing portion of the radial neck was resected and the stem was advanced. Making a neck cut distal to a 5-mm-long, 1-mm-wide cortical notch does not confer added stability. Thus, surgeons can preserve bone stock and avoid an aggressive neck cut.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2017.09.037DOI Listing

Publication Analysis

Top Keywords

radial neck
16
radial head
16
radial
9
initial stability
8
cut stem
8
cortical notch
8
notch
5
stem
5
micromotion
5
neck
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!