Statement Of Problem: Some complete denture wearers report difficulty with daily activities, especially activities related to denture retention and stability. However, no standard criteria are available for professionally based assessment of complete denture quality.

Purpose: The purpose of this clinical study was to determine the association between professionally based assessment of complete denture quality, evaluated by conventional and Chulalongkorn University (CU)-modified Kapur criteria and multiple patient-based outcomes: oral health-related quality of life (OHRQoL), eating satisfaction, and masticatory performance. The sensitivity and specificity of these criteria in estimating the outcomes were investigated.

Material And Methods: The participants were 126 individuals with removable acrylic resin complete dentures. Denture retention and stability were scored based on the Kapur method, with excellent intraobserver reliability indicated by a Kappa score of 0.91 to 0.99. The clinical quality of the complete denture was classified according to conventional and CU-modified Kapur criteria. The participants were interviewed for OHRQoL by using the Thai version of the Oral Impacts on Daily Performances (OIDP) index and responses were reported as the absence or presence of oral impacts. Participants' satisfaction eating with their dentures was determined by using a 5-point Likert scale and dichotomized into satisfied and dissatisfied categories. Masticatory performance was evaluated by the multiple sieve method of peanut mastication. After adjusting for covariates, the associations between denture quality and overall and condition-specific (CS) impacts on eating and on eating satisfaction were analyzed by using binary logistic regression, while its association with masticatory performance was determined using linear regression. Goodness-of-fit post estimation was conducted to determine the sensitivity and specificity of each denture quality criterion in estimating patient-based outcomes.

Results: Complete denture retention and stability, evaluated by conventional and CU-modified Kapur criteria, were associated with multiple patient-based outcomes. However, denture stability showed a stronger association than retention. The CU-modified criteria assessed the quality of maxillary and mandibular dentures individually and revealed a higher sensitivity in estimating all patient-based outcomes.

Conclusions: Retention and stability were important indicators in estimating the masticatory ability and OHRQoL of complete denture wearers. The CU-modified Kapur criteria can identify impaired masticatory ability and OHRQoL in complete denture wearers better than conventional criteria.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2017.09.010DOI Listing

Publication Analysis

Top Keywords

complete denture
32
retention stability
20
denture wearers
16
cu-modified kapur
16
kapur criteria
16
denture
13
denture retention
12
denture quality
12
masticatory performance
12
criteria
9

Similar Publications

CAD-CAM complete digital dentures: An improved clinical and laboratory workflow.

J Prosthet Dent

December 2024

Associate Professor and Department Head, Department of Prosthodontics, University of Ferrara, Ferrara, Italy.

The purpose of this article was to present a novel clinical workflow for the fabrication of complete dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) technology. The dental technique consists of 3 clinical steps and 2 laboratory phases that result in the production of 2 CAD-CAM milled complete denture bases with prefabricated teeth. The integration of analog and digital procedures and materials maximizes their benefits in the planning and fabrication of complete dentures, with the goal of improving clinical outcomes.

View Article and Find Full Text PDF

Purpose: To compare digitally fabricated complete dentures to conventionally fabricated dentures using patient- and clinician-reported outcome measures.

Methods: This review was structured according to PRISMA guidelines with the protocol registered in the PROSPERO database (CRD42024526069). An electronic search of the databases with a defined search strategy was completed within PubMed/MEDLINE and Web of Science from January 2000 to March 2024.

View Article and Find Full Text PDF

Full-mouth rehabilitation of a patient with implant-supported fixed dental prostheses using CAD-CAM frameworks.

Prim Dent J

December 2024

Ilser Turkyilmaz DMD, PhD Associate Dean of Digital Innovation, Professor and Chair, Department of Comprehensive Care, School of Dental Medicine, Case Western Reserve University, Cleveland, Ohio, USA.

Conventional complete denture wearers often complain of lack of stability and overall discomfort with their prostheses. The advent of dental implants and advanced prosthetic methods have greatly improved this struggle for edentulous patients. The utilisation of computer-aided design and computer-aided manufacturing (CAD-CAM) technology has only further enhanced the capabilities of dental practitioners to rapidly and accurately restore edentulism.

View Article and Find Full Text PDF

Statement Of Problem: Denture stomatitis (DS) is a common oral disorder in patients with complete maxillary dentures. Typical treatments such as nystatin or azoles lead to drug resistance after a long period. Several studies have shown the antifungal activity of statins against Candida albicans; however, studies on the antifungal effect of atorvastatin against DS are lacking.

View Article and Find Full Text PDF

Purpose: To compare the trueness of the tissue surface of the complete denture base among the digital cutting complete denture, the digital 3D printing complete denture and the conventional complete denture.

Methods: Three edentulous patients were selected, and three complete dentures were made for each case. Cutting dentures (cutting group), 3D printed dentures(printing group) were considered as the experimental groups, traditional dentures (traditional group) were considered as the control group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!