Ultrasound Determination of the Femoral Head-Neck Alpha Angle.

Ultrasound Med Biol

Department of Medical Imaging & Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Australia.

Published: February 2018

The femoral head-neck alpha angle is used to quantify the degree of femoral head asphericity in patients suspected of cam-type femoroacetabular impingement. The measurement was first performed using magnetic resonance imaging and, more recently, three-dimensional computed tomography (CT). We set out to determine whether the alpha angle could be reliably measured using ultrasound. Patients were recruited from a cohort presenting for CT of the hip. Alpha angles were calculated following the departmental protocol by institutionally accredited radiographers. After the CT, patients were imaged with ultrasound and the alpha angle calculated from the ultrasound image by a sonographer blinded to the CT result. Statistical comparison of the two methods was performed with the Bland-Altman test using SPSS (version 21.0, Chicago, USA), and a p < 0.05 afforded significance. Twenty-eight patients were recruited. Eleven patients were bilateral examinations, providing 39 hips for analysis. There were 15 females and 13 males, with 21 right and 18 left hips examined. Average patient age (±standard deviation) was 40 y (±13.9 y). Mean (±standard deviation) measurements for CT and ultrasound were 62.5° (±14.2°) and 64.5° (±12.6°), respectively. The mean absolute difference between the two methods was 10.5° (95% confidence interval 6.9°-14.0°). Sensitivity of each individual ultrasound measurement was 91.3%. The specificity of ultrasound was 43.75%. The positive predictive value was 0.7, and the negative predictive value was 0.78. Overall accuracy of the ultrasound-derived alpha angle was calculated at 0.718. Ultrasound demonstrates good sensitivity and good negative predictive value in calculation of the femoral head-neck alpha angle compared with CT; however, specificity is low. Ultrasound measurement of the alpha angle can provide objective evidence of cam-type femoroacetabular impingement in symptomatic patients and can direct patients to more established imaging techniques where appropriate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2017.10.006DOI Listing

Publication Analysis

Top Keywords

alpha angle
16
femoral head-neck
8
head-neck alpha
8
alpha
5
ultrasound
4
ultrasound determination
4
determination femoral
4
angle
4
angle femoral
4
angle quantify
4

Similar Publications

Asymptomatic female softball pitchers have altered hip morphology and cartilage composition.

Sci Rep

January 2025

La Trobe Sport & Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, Australia.

Few studies have explored hip morphology and cartilage composition in female athletes or the impact of asymmetric repetitive loading, such as occurs during softball pitching. The current cross-sectional study assessed bilateral bony hip morphology on computed tomography imaging in collegiate-level softball pitchers ('Pitch1', n = 25) and cross-country runners ('Run', n = 13). Magnetic resonance imaging was used to assess cartilage relaxation times in a second cohort of pitchers ('Pitch2', n = 10) and non-athletic controls ('Con', n = 4).

View Article and Find Full Text PDF

A small but growing set of radical SAM (-adenosyl-l-methionine) enzymes catalyze the radical mediated dehydration or dehydrogenation of 1,2-diol substrates. In some cases, these activities can be interchanged via minor structural perturbations to the reacting components raising questions regarding the relative importance of hyperconjugation, proton circulation and leaving group stability in determining the reaction outcome. The present work describes trapping and electron paramagnetic resonance (EPR) characterization of an α-hydroxyalkyl radical intermediate during dehydration and dehydrogenation of cytosylglucuronic acid and its derivatives catalyzed by the radical SAM enzyme BlsE and its Glu189Ala mutant from the blasticidin S biosynthetic pathway.

View Article and Find Full Text PDF

To reveal the microstructural evolution and stress-strain distribution of 780 MPa-grade ferrite/martensite dual-phase steel during a uniaxial tensile deformation process, the plastic deformation behavior under uniaxial tension was studied using in situ EBSD and crystal plastic finite element method (CPFEM). The results showed that the geometrically necessary dislocations (GND) in ferrite accumulated continuously, which is conducive to the formation of grain boundaries, but the texture distribution did not change significantly. The average misorientation angle decreased and the proportion of low-angle grain boundaries increased with the increase of strain.

View Article and Find Full Text PDF

: Neonatal sepsis is a serious condition with high mortality, especially in premature and low-birth-weight neonates. This study aims to examine whether the haemostatic profile of neonates with sepsis defers depending on the type of bacteria (Gram-positive or Gram-negative), by using the method of Rotational Thromboelastometry (ROTEM). : This single-centre prospective cohort study was conducted on 128 neonates with sepsis, including 95 cases caused by Gram-negative pathogens and 33 cases caused by Gram-positive bacteria.

View Article and Find Full Text PDF

A water-soluble polysaccharide from foxtail millet (FM-D1) was isolated and purified through gradient ethanol precipitation and column chromatography. Size-Exclusion Chromatography-Multi-Angle Light Scattering-Refractive Index (SEC-MALLS-RI) and high-performance anion-exchange chromatography (HPAEC) analyses revealed that FM-D1 constitutes a highly purified neutral polysaccharide exclusively composed of glucose as the sugar unit, with a molecular weight of 14.823 kDa.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!