Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Study Design: Cross-sectional repeated measures.
Objectives: To quantify the effects of posture and measurement site on the inter-recti distance (IRD) and investigate the reliability of IRD measurement using ultrasound imaging in different postures.
Background: The linea alba connects the rectus abdominis muscles anteriorly and the width is known as the IRD. The IRD is usually measured in crook-lying and is the primary outcome measure to assess for a divarication of recti abdominis (DRA). The effects of posture and measurement site on the IRD have not been investigated.
Methods: Ultrasound imaging was used to measure IRD in 41 women ≥8 weeks postpartum. The IRD was measured at three sites (superior-umbilicus, umbilicus and inferior-umbilicus), in three postures (crook-lying, sitting and standing), and repeated one-week later. The effects of posture and site were investigated using one-way ANOVAs. Reliability was analysed using Intraclass correlation coefficients (ICCs), Bland Altman analyses, standard error of measurement and minimal detectable change.
Results: The IRD was wider when standing vs. lying at both the superior-umbilicus and umbilicus by 0.30 cm (95% CI 0.21 to 0.39) and 0.20 cm (0.11-0.30) respectively (p < 0.001). Measurements at the inferior-umbilicus were, on average, 1.6 and 2.1 cm narrower than superior-umbilicus and umbilicus sites, respectively (p < 0.001). There was high intra-rater reliability within-session (ICC) and between-session (ICC) at all sites measured.
Conclusion: The IRD can be measured reliably at all sites and postures. The IRD is wider at superior-umbilicus and umbilicus when upright compared with lying. There is a difference in IRD between all sites measured.