Standardization of hemipelvis alignment for in vitro biomechanical testing.

J Orthop Res

Department of Industrial Engineering, School of Engineering and Architecture, Alma Mater Studiorum-Università di Bologna, Via Umberto Terracini 24/26, Bologna, 40131, Italy.

Published: June 2018

Although in vitro biomechanical tests are regularly performed, the definition of a suitable reference frame for hemipelvic specimens is still a challenge. The aims of the present study were to: (i) define a reference frame for the human hemipelvis suitable for in vitro applications, based on robust anatomical landmarks; (ii) identify the alignment of a hemipelvis based on the alignment of a whole pelvis (including right/left and male/female differences); (iii) identify the relative alignment of the proposed in vitro reference frame with respect to a reference frame commonly used in gait analysis; (iv) create an in vitro alignment procedure easy, robust and inexpensive; (v) quantify the intra-operator repeatability and inter-operator reproducibility of the procedure. A procedure to univocally identify the anatomical landmarks was created, exploiting the in vitro accessibility of the specimen's surface. Through the analysis on 53 CT scans (106 hemipelvises), the alignment of the hemipelvis based on the alignment of a whole pelvis was analyzed: differences between male/female and right/left hemipelvises were not statistically significant To overcome the uncertainty in the identification of the acetabular rim, a standard acetabular plane was defined. An alignment procedure was developed to implement such anatomical reference frame. The intra-operator repeatability and the inter-operator reproducibility were quantified with four operators, on male and female hemipelvises. The intra-operator repeatability was better than 1.5°. The inter-operator reproducibility was better than 2.0°. Alignment in the transverse plane was the most repeatable. The presented procedure to align hemipelvic specimens is sufficiently robust, standardized, and accessible. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1645-1652, 2018.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.23825DOI Listing

Publication Analysis

Top Keywords

reference frame
20
intra-operator repeatability
12
inter-operator reproducibility
12
alignment
9
vitro biomechanical
8
hemipelvic specimens
8
anatomical landmarks
8
alignment hemipelvis
8
hemipelvis based
8
based alignment
8

Similar Publications

Introduction: Sacroiliac luxation is a common traumatic feline injury, with the small size of the sacral body being a challenge for surgical stabilization. This study compared an innovative computer-guided drilling method with the conventional fluoroscopy-controlled freehand technique. Neuronavigation, using CT-based planning and real-time tracking, was evaluated against the freehand method for accuracy and time efficiency.

View Article and Find Full Text PDF

A key question about social media use is whether it constitutes an addiction. A possible frame of reference to investigate this question is the Incentive Sensitizations Theory (IST), as it provides a solid empirical background to understand the motivational and hedonic aspects of problematic behaviors. A central assumption of IST that addiction-related cues play a pivotal role in addictive behaviors has remained relatively understudied in the context of social media use.

View Article and Find Full Text PDF

This paper introduces an interferometer for single-shot areal quantitative phase imaging at two wavelengths simultaneously, suitable for use with low coherence sources. It operates in reflection geometry with on-axis illumination, so that it can be conveniently applied to surface texture measurements. The system consists of two identical 4f systems forming the reference and sample arm.

View Article and Find Full Text PDF

Ghost holography has attracted notable applied interest in the modern quantitative imaging applications with the futuristic features of complex field recovery in the diversified imaging scenarios. However, the utilization of digital holography in ghost frame works introduces space bandwidth or time bandwidth restrictions in the implementation of the technique in applied domains. Here, we propose and demonstrate a quantitative ghost phase imaging approach with holographic ghost diffraction scheme in combination with the phase-shifting technique.

View Article and Find Full Text PDF

A criterion for the characterization of the retardance effects produced by depolarizing and nondepolarizing linear media on interacting light is established based on Mueller matrices algebra. A consistent general description of retardance properties is performed by means of a serial decomposition of the Mueller matrix into three components, namely an element that encompasses the enpolarizing and depolarizing properties sandwiched by two elliptical retarders containing complete and decoupled information on retardance. The inherent ambiguity derived from the coincident formal structure of rotation matrices and circular retarders is removed though the introduction of the entrance and exit intrinsic reference frames, leading to the concepts of the intrinsic entrance and exit linear retarders, which are defined from the Mueller matrix itself and that are independent of the laboratory reference frames used to represent the incident and emerging polarized light beams, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!