Aims: Vagal responses (VR) during left atrial ablation for atrial fibrillation (AF) treatment have been reported to be associated with less recurrences, presumably because they are a sign of ganglionated plexi modification. Our objective was to evaluate whether coincidentally elicited VR during left atrial ablation are associated with lower AF recurrence rates.
Methods And Results: This is a post hoc analysis of a prospective study of 291 patients with paroxysmal AF undergoing radiofrequency pulmonary vein isolation (PVI). Vagal responses were defined as episodes of heart rate <40 bpm or asystole lasting >5 s elicited during energy application. Sixty-eight patients (23.4%) had a VR during ablation. In Kaplan-Meier analysis, mean recurrence-free survival was 449 days (95% confidence interval 411-488) in patients with VR when compared with 435 days (95% confidence interval 415-455) in those without (P = 0.310). The 12-month recurrence rate estimates were 25 and 27%, respectively. In an unadjusted Cox model, VR was associated with an odds ratio for recurrence of 0.77 (95% confidence interval 0.46-1.28).
Conclusion: Coincidentally elicited VR during radiofrequency PVI in patients with paroxysmal AF do not appear to be related to lower risk of arrhythmia recurrence. This may mean that, even if a VR is truly a sign of coincidental ablation of a ganglionated plexus, this does not necessarily mean that a therapeutic modification has been effected, at least to a degree associated with clinical benefit.