OBJECTIVE High-quality studies that compare outcomes of open and minimally invasively placed pedicle screws for adult spinal deformity are needed. Therefore, the authors compared differences in complications from a circumferential minimally invasive spine (MIS) surgery and those from a hybrid surgery. METHODS A retrospective review of a multicenter database of patients with spinal deformity who were treated with an MIS surgery was performed. Database inclusion criteria included an age of ≥ 18 years and at least 1 of the following: a coronal Cobb angle of > 20°, a sagittal vertical axis of > 5 cm, a pelvic incidence-lumbar lordosis angle of > 10°, and/or a pelvic tilt of > 20°. Patients were propensity matched according to the levels instrumented. RESULTS In this database, a complete data set was available for 165 patients, and after those who underwent 3-column osteotomy were excluded, 137 patients were available for analysis; 76 patients remained after propensity matching (MIS surgery group 38 patients, hybrid surgery group 38 patients). The authors found no difference in demographics, number of levels instrumented, or preoperative and postoperative radiographic results. At least 1 complication was suffered by 55.3% of patients in the hybrid surgery group and 44.7% of those in the MIS surgery group (p = 0.359). Patients in the MIS surgery group had significantly fewer neurological, operative, and minor complications than those in the hybrid surgery group. The reoperation rates in both groups were similar. The most common complication category for the MIS surgery group was radiographic and for the hybrid surgery group was neurological. Patients in both groups experienced postoperative improvement in their Oswestry Disability Index and visual analog scale (VAS) back and leg pain scores (all p < 0.05); however, MIS surgery provided a greater reduction in leg pain according to VAS scores. CONCLUSIONS Overall complication rates in the MIS and hybrid surgery groups were similar. MIS surgery resulted in significantly fewer neurological, operative, and minor complications. Reoperation rates in the 2 groups were similar, and despite complications, the patients reported significant improvement in their pain and function.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2017.8.FOCUS17479 | DOI Listing |
EClinicalMedicine
February 2025
Department of Breast and Gynaecological Surgery, Institut Curie, Paris, France.
Background: Randomized clinical trials (RCTs) are fundamental to evidence-based medicine, but their real-world impact on clinical practice often remains unmonitored. Leveraging large-scale real-world data can enable systematic monitoring of RCT effects. We aimed to develop a reproducible framework using real-world data to assess how major RCTs influence medical practice, using two pivotal surgical RCTs in gynaecologic oncology as an example-the LACC (Laparoscopic Approach to Cervical Cancer) and LION (Lymphadenectomy in Ovarian Neoplasms) trials.
View Article and Find Full Text PDFBrain Spine
December 2024
Department of Neurosurgery, University Medical Center Mainz, Mainz, Germany.
Introduction: The management of de novo non-specific spinal infections (spondylodiscitis - SD) remains inconsistent due to varying clinical practices and a lack of high-level evidence, particularly regarding the indications for surgery.
Research Question: This study aims to develop consensus recommendations for the diagnosis and management of SD, addressing diagnostic modalities, surgical indications, and treatment strategies.
Material And Methods: A Delphi process was conducted with 26 experts from the European Association of Neurosurgical Societies (EANS).
J Clin Med
January 2025
Servicio de Cirugía Ortopédica y Traumatología, Hospital La Paz-IdiPaz, 28046 Madrid, Spain.
: Surgical accuracy in total knee replacement (TKR) may vary with the surgeon, the patient preoperative deformity, and the guiding system to perform the procedure. Navigation systems attempt to increase the intraoperative information the surgeon requires to make the appropriate decisions, sometimes associating cumbersome procedures and unclear effectiveness to place the implant more precisely than conventional instruments. : We conducted a retrospective case-control study with prospective data collection of radiographic measurements (alignment, joint line and patellar height) in a sample of 100 consecutive patients receiving TKR Optetrak Logic PS, either with standard surgical technique with Trulion Instrumentation ( = 59) or with the Guided Personalized Surgery (GPS) system ( = 41).
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Department of Orthopaedics, Mass General Brigham, Boston, Massachusetts.
Case: A 51-year-old male polytrauma patient presented with bilateral calcaneus fractures after a fall. This report describes treatment of his right comminuted Sanders IV calcaneus fracture with percutaneous open reduction internal fixation (ORIF) and minimally invasive surgery (MIS) primary subtalar fusion to restore alignment and preserve soft tissue.
Conclusion: Unlike traditional open approaches, which are prone to wound complications due to larger incisions, our approach of maintaining fracture alignment during joint preparation using an MIS burr for acute posttrauma subtalar arthrodesis and percutaneous ORIF appears to have reduced these risks, resulting in successful radiological healing and functional recovery at 1-year follow-up.
Tzu Chi Med J
July 2024
Neuroscience Spine Center, Taichung Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taichung, Taiwan.
Objectives: Minimally invasive surgery (MIS) has emerged as a promising alternative to conventional open techniques in the management of adolescent idiopathic scoliosis (AIS).
Materials And Methods: This study presents a case series of six patients who underwent MIS for AIS at a spine center, employing a synergistic blend of intraoperative fluoroscopy, cone-beam computed tomography scans, and three-dimensional navigation technology. The surgical procedures were meticulously guided, with a focus on ensuring safety and precision in posterior pedicle fixation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!