Background: The optimum pattern of pedicle screw (PS) fixation during long-segment thoracic fixation has not been determined.

Objective: To evaluate rod stress and construct stability with minimal, alternating, skipped, and bilateral PS constructs in the iatrogenically destabilized thoracic spine.

Methods: Eight cadaveric thoracic specimens (T3-T12) were initially tested intact to ±5 Nm using a custom 6 degree-of-freedom spine testing apparatus in flexion-extension (FE), lateral bending (LB), and axial rotation. Specimens were instrumented with T4-T10 bilateral PS, with Ponte osteotomies to introduce instability. Rods were bent to fit the PS and then spines were tested with the minimal, alternating, skipped, and bilateral fixation patterns. Range of motion (ROM) was calculated from T4-T10 and segmentally. In addition, strain gauges fixed to the spinal rods measured rod stress under FE and LB. Results were compared using ANOVA and post hoc Holm Sidak tests.

Results: All fixation patterns provided significant reductions in ROM with respect to the intact spine. In all motion planes, minimal provided the least amount of rigidity, while bilateral provide the greatest; however, no statistically significant differences were detected in FE. In LB and axial rotation, skipped, alternating, and bilateral were all significantly more rigid than minimal (P < .01). Rod strains were greatest under LB and correlated with overall construct ROM, where bilateral had significantly lower strain than the other patterns (P < .05).

Conclusion: All constructs effectively decreased thoracic ROM. There was significant improvement in stabilization and decreased rod stress when more fixation points beyond the minimal construct were included.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ons/opx051DOI Listing

Publication Analysis

Top Keywords

rod stress
12
pedicle screw
8
thoracic fixation
8
minimal alternating
8
alternating skipped
8
skipped bilateral
8
axial rotation
8
fixation patterns
8
fixation
6
bilateral
6

Similar Publications

Osteointegration, the effective coupling between an implant and bone tissue, is a highly intricate biological process. The initial stages of bone-related immunomodulation and cellular colonization play crucial roles, but have received limited attention. Herein, a novel supramolecular co-assembled coating of strontium (Sr)-doped metal polyphenol networks (MPN) modified with c(RGDfc) is developed and well-characterized, for eliciting an early immunomodulation and cellular colonization.

View Article and Find Full Text PDF

A Novel Dynamic Growth Rod Inducing Spinal Growth Modulation for the Correction of Spinal Deformities.

JOR Spine

March 2025

Beijing Key Laboratory for Design and Evaluation Technology of Advanced Implantable & Interventional Medical Devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering Beihang University Beijing China.

Background: Growth rods are the gold standard for treating early-onset scoliosis (EOS). However, current treatments with growth rods do not optimize spinal growth in EOS patients, and frequent distraction surgeries significantly increase complications, imposing considerable economic and psychological burdens on patients. An improved growth rod is urgently required to address the need for dynamic growth and external regulation.

View Article and Find Full Text PDF

Effect of Temperature and Stress on Creep Behavior of (TiB + TiC + YO)/α-Ti Composite.

Materials (Basel)

December 2024

National Key Laboratory for Precision Hot Processing of Metals, Harbin Institute of Technology, Harbin 150001, China.

In this study, a (TiB + TiC + YO)/α-Ti composite was prepared by induction skull melting to investigate its creep behavior and microstructure evolution under different temperatures and stresses. The results show that the microstructure of the composite in the as-cast state is a basket-weave structure, and the main phase composition is α lamella, containing a small amount of β phase and equiaxed α phase. The creep life of the composite decreases significantly when the temperature is increased from 650 °C to 700 °C, and the steady-state creep rate is increased by 1 to 2 orders of magnitude.

View Article and Find Full Text PDF

Mechanisms of Rhodopsin-Related Inherited Retinal Degeneration and Pharmacological Treatment Strategies.

Cells

January 2025

Department of Pharmacology, School of Medicine, Case Western Reserve University, 10900 Euclid Ave., Cleveland, OH 44106, USA.

Retinitis pigmentosa (RP) is a hereditary disease characterized by progressive vision loss ultimately leading to blindness. This condition is initiated by mutations in genes expressed in retinal cells, resulting in the degeneration of rod photoreceptors, which is subsequently followed by the loss of cone photoreceptors. Mutations in various genes expressed in the retina are associated with RP.

View Article and Find Full Text PDF

Flurbiprofen (FBP) is poorly water-soluble BCS class II drug with anti-inflammatory and analgesic effects, used to treat arthritis and degenerative joint diseases. This study was aimed to develop SNEDDS loaded with FBP. Six SNEDDS using two oils olive oil (F, F, F) and castor oil (F, F, F) with three different Smix ratios consisting of Tween 20 and PEG 400 (1:1, 1:2, 2:1) were prepared and characterized.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!