An Advanced Hybrid Technique of DCS and JSRC for Telemonitoring of Multi-Sensor Gait Pattern.

Sensors (Basel)

College of Mathematics and Informatics, Fujian Normal University, Fuzhou 350117, China.

Published: November 2017

The jointly quantitative analysis of multi-sensor gait data for the best gait-classification performance has been a challenging endeavor in wireless body area networks (WBANs)-based gait telemonitoring applications. In this study, based on the joint sparsity of data, we proposed an advanced hybrid technique of distributed compressed sensing (DCS) and joint sparse representation classification (JSRC) for multi-sensor gait classification. Firstly, the DCS technique is utilized to simultaneously compress multi-sensor gait data for capturing spatio-temporal correlation information about gait while the energy efficiency of the sensors is available. Then, the jointly compressed gait data are directly used to develop a novel neighboring sample-based JSRC model by defining the sparse representation coefficients-inducing criterion (SRCC), in order to yield the best classification performance as well as a lower computational time cost. The multi-sensor gait data were selected from an open wearable action recognition database (WARD) to validate the feasibility of our proposed method. The results showed that when the comparison ratio and the number of neighboring samples are selected as 70% and 40%, respectively, the best accuracy (95%) can be reached while the lowest computational time spends only 60 ms. Moreover, the best accuracy and the computational time can increase by 5% and decrease by 40 ms, respectively, when compared with the traditional JSRC techniques. Our proposed hybrid technique can take advantage of the joint sparsity of data for jointly processing multi-sensor gait data, which greatly contributes to the best gait-classification performance. This has great potential for energy-efficient telemonitoring of multi-sensor gait.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5751380PMC
http://dx.doi.org/10.3390/s17122764DOI Listing

Publication Analysis

Top Keywords

multi-sensor gait
28
gait data
20
hybrid technique
12
computational time
12
gait
10
advanced hybrid
8
telemonitoring multi-sensor
8
best gait-classification
8
gait-classification performance
8
joint sparsity
8

Similar Publications

: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis.

View Article and Find Full Text PDF

This study aims to integrate a convolutional neural network (CNN) and the Random Forest Model into a rehabilitation assessment device to provide a comprehensive gait analysis in the evaluation of movement disorders to help physicians evaluate rehabilitation progress by distinguishing gait characteristics under different walking modes. Equipped with accelerometers and six-axis force sensors, the device monitors body symmetry and upper limb strength during rehabilitation. Data were collected from normal and abnormal walking groups.

View Article and Find Full Text PDF

A Novel, Wearable Inertial Measurement Unit for Stroke Survivors: Validity, Acceptability, and Usability.

Arch Phys Med Rehabil

June 2024

Division of Biokinesiology and Physical Therapy, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, CA; Department of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, CA.

Objective: To establish the concurrent validity, acceptability, and sensor optimization of a consumer-grade, wearable, multi-sensor system to capture quantity and quality metrics of mobility and upper limb movements in stroke survivors.

Design: Single-session, cross-sectional.

Setting: Clinical research laboratory.

View Article and Find Full Text PDF

Background: Falls are common and dangerous for stroke survivors. Current fall risk assessment methods rely on subjective scales. Objective sensor-based methods could improve prediction accuracy.

View Article and Find Full Text PDF

Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device.

Sci Rep

January 2024

Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, The Catalyst 3 Science Square, Room 3.27, Newcastle Upon Tyne, NE4 5TG, UK.

Article Synopsis
  • - The study evaluated the accuracy of a wearable device designed to estimate walking speed in individuals, including those with various health conditions and healthy older adults, over a 2.5-hour period in both laboratory and real-world settings.
  • - Results showed that the device's walking speed estimates had a mean absolute error ranging from 0.06 to 0.13 m/s, indicating good to excellent agreement with a multi-sensor reference system, particularly for participants without significant gait impairments.
  • - The findings underscore the importance of validating technology for clinical use, as accuracy varied with factors like task complexity and walking duration, suggesting the need for thorough testing before implementation in real-world mobility assessments.