Scalable Production of Graphene-Based Wearable E-Textiles.

ACS Nano

The National Graphene Institute (NGI), The University of Manchester, Booth Street East, Manchester M13 9PL, United Kingdom.

Published: December 2017

Graphene-based wearable e-textiles are considered to be promising due to their advantages over traditional metal-based technology. However, the manufacturing process is complex and currently not suitable for industrial scale application. Here we report a simple, scalable, and cost-effective method of producing graphene-based wearable e-textiles through the chemical reduction of graphene oxide (GO) to make stable reduced graphene oxide (rGO) dispersion which can then be applied to the textile fabric using a simple pad-dry technique. This application method allows the potential manufacture of conductive graphene e-textiles at commercial production rates of ∼150 m/min. The graphene e-textile materials produced are durable and washable with acceptable softness/hand feel. The rGO coating enhanced the tensile strength of cotton fabric and also the flexibility due to the increase in strain% at maximum load. We demonstrate the potential application of these graphene e-textiles for wearable electronics with activity monitoring sensor. This could potentially lead to a multifunctional single graphene e-textile garment that can act both as sensors and flexible heating elements powered by the energy stored in graphene textile supercapacitors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5911806PMC
http://dx.doi.org/10.1021/acsnano.7b05921DOI Listing

Publication Analysis

Top Keywords

graphene-based wearable
12
wearable e-textiles
12
graphene oxide
8
graphene e-textiles
8
graphene e-textile
8
graphene
7
e-textiles
5
scalable production
4
production graphene-based
4
wearable
4

Similar Publications

Thermoelectric porous laser-induced graphene-based strain-temperature decoupling and self-powered sensing.

Nat Commun

January 2025

Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania, 16802, USA.

Despite rapid developments of wearable self-powered sensors, it is still elusive to decouple the simultaneously applied multiple input signals. Herein, we report the design and demonstration of stretchable thermoelectric porous graphene foam-based materials via facile laser scribing for self-powered decoupled strain and temperature sensing. The resulting sensor can accurately detect temperature with a resolution of 0.

View Article and Find Full Text PDF
Article Synopsis
  • Miniature energy storage devices, crucial for wearable electronics, are explored through the fabrication of flexible micro-supercapacitors (MSCs) made from laser-induced graphene using graphene oxide (GO) on polyimide film.* -
  • The study measured the areal capacitance of these MSCs with a gel electrolyte, observing a significant initial increase that stabilized after six days of testing.* -
  • The optimized MSC, using the best concentration of GO, showed a high capacitance of 10.07 mF cm and maintained 87.9% capacitance retention after 5000 charge-discharge cycles, proving its effectiveness for flexible applications.*
View Article and Find Full Text PDF

A new approach has recently emerged in graphene synthesis by direct laser writing (LIG), which is highly economical and scalable, unlike previous methods. Here, the sputtering method has been used to coat silver onto the laser-induced graphene-based sensor. The results demonstrate that the chosen approach substantially impacts the expected outcomes.

View Article and Find Full Text PDF

A surface modified laser-induced graphene based flexible biosensor for multiplexed sweat analysis.

J Mater Chem B

December 2024

Department of Physics, School of Natural Sciences, Shiv Nadar Institution of Eminence (SNIoE), Deemed to be University, Delhi-NCR, Greater Noida, 201314, India.

The growing popularity of electrochemical sensors featuring non-invasive biosensing technologies has generated significant enthusiasm for continuous monitoring of bodily fluid biomarkers, potentially aiding in the early detection of health issues in individuals. However, detection of multiple biomarkers in complex biofluids often necessitates a high-density array which creates a challenge in achieving cost-effective fabrication methods. To overcome this constraint, this work reports the fabrication of an electrochemical sensor utilizing a NiO-TiCT MXene-modified flexible laser-induced graphene (LIG) electrode for the separate and concurrent analysis of ascorbic acid (AA), dopamine (DA), and uric acid (UA) in human sweat and also addresses the deficiencies in the existing state of the art by offering a cost-efficient and high-performance sensor that mitigates the degrading constraints of conventional LIG electrodes.

View Article and Find Full Text PDF

Wearable electronic textiles (e-textiles) are transforming personalized healthcare through innovative applications. However, integrating electronics into textiles for e-textile manufacturing exacerbates the rapidly growing issues of electronic waste (e-waste) and textile recycling due to the complicated recycling and disposal processes needed for mixed materials, including textile fibers, electronic materials, and components. Here, first closed-loop recycling for wearable e-textiles is reported by incorporating the thermal-pyrolysis of graphene-based e-textiles to convert them into graphene-like electrically conductive recycled powders.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!