An MR/MRI compatible core holder with the RF probe immersed in the confining fluid.

J Magn Reson

UNB MRI Centre, Department of Physics, University of New Brunswick, Fredericton, New Brunswick E3B 5A3, Canada. Electronic address:

Published: January 2018

AI Article Synopsis

Article Abstract

An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both H and F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF was imaged as a high pressure gas and as a supercritical fluid.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2017.11.006DOI Listing

Publication Analysis

Top Keywords

open frame
20
core holder
16
frame probe
12
high pressure
12
mr/mri compatible
8
probe immersed
8
confining fluid
8
frame structure
8
probe
7
core
5

Similar Publications

Background: Sugarcane is cultivated globally and affected by more than 125 pathogens, which lead to various plant diseases. In recent years, high-throughput sequencing (HTS)-based genome analyses have been broadly adopted for the discovery of both characterized and un-characterized viruses from plant samples. In this study, the HTS data of sugarcane pooled sample retrieved from sequence read archive (SRA) were de novo re-assembled using CLC Genomic Workbench.

View Article and Find Full Text PDF

Objective: Lower limb malalignment can complicate symptoms and accelerate knee osteoarthritis (OA), necessitating consideration in study population selection. In this study, we develop and validate a deep learning model that classifies leg alignment as "normal" or "malaligned" from knee antero-posterior (AP)/postero-anterior (PA) radiographs alone, using an adjustable hip-knee-ankle (HKA) angle threshold.

Material And Methods: We utilized 8878 digital radiographs, including 6181 AP/PA full-leg x-rays (LLRs) and 2697 AP/PA knee x-rays (2292 with positioning frame, 405 without).

View Article and Find Full Text PDF

T cell-based immunotherapies targeting antigens on tumor cells have shown efficacy as anti-cancer treatments. While neoantigens are created by somatic mutations acquired during tumorigenesis, allogeneic stem cell transplantation as treatment for hematological malignancies exploits minor histocompatibility antigens encoded by genetic differences between patients and donors. Screening methods to predict neoantigens and minor histocompatibility antigens typically consider only conventional antigens created by nonsynonymous mutations or polymorphisms coding for amino acid changes in canonical open reading frames (ORFs).

View Article and Find Full Text PDF

Severe cases of COVID-19 are associated with immune responses that lead to a surge in inflammatory molecules, resulting in multi-organ failure and death. This significant increase in inflammatory factors is triggered by viral proteins. Open reading frame 8 (ORF8) has received particular attention as a unique accessory protein of SARS-CoV-2.

View Article and Find Full Text PDF

Introduction: The number of vertical artefacts (VAs) in lung ultrasound (LUS) impacts patients' clinical management. This study aimed to demonstrate the influence of ultrasound settings on the number of VAs in patients under invasive mechanical ventilation (IMV).

Methods: Patients under IMV were recruited for LUS, including three breathing cycles with a motionless curvilinear probe on the thoracic region with the most VAs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!