Background Non-invasive evaluation of coronary stent patency by coronary computed tomography angiography (cCTA) remains challenging. Multiple studies showed that CT technology but also individual stent design strongly influence the assessability of coronary stents by cCTA. Purpose To expand the available data on cCTA characteristics of coronary stents by 24 novel types to help interpreting examinations of patients after stent placement and selecting which stents are suitable for assessment by cCTA. Material and Methods Twenty-four novel coronary stents (17 cobalt-chromium, six stainless-steel, one platinum-chromium) were examined in a coronary phantom. Standard cCTA parameters with stent-specific algorithms were used. Image quality was quantified for each stent using established parameters (in-stent attenuation alteration and visible lumen diameter). Results Most stents (n = 14) showed lumen visibilities of 45-55%. No severe restriction of lumen visibility (>60%) was found. The majority of stents (n = 13) caused only small intraluminal attenuation deviations and no severe alterations (>20%) were found. When grouped by manufacturing material, no significant differences were found between cobalt-chromium and stainless-steel with identical mean visible diameters (1.52 ± 0.17 mm vs. 1.52 ± 0.13 mm) and comparable attenuation alterations (35.04 ± 16.56 HU vs. 21.25 ± 14.60 HU). The only platinum-chromium stent showed a smaller visible diameter (1.23 mm) and higher attenuation alteration (41.70 HU), but was also deemed to be assessable by cCTA. Conclusion All 24 novel evaluated stents are eligible for non-invasive evaluation by cCTA without significant differences between cobalt-chromium and stainless-steel stents. This updated catalogue of CT appearances of current coronary stents may serve as reference when taking care of patients with stents in need of coronary imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0284185117744227DOI Listing

Publication Analysis

Top Keywords

coronary stents
20
cobalt-chromium stainless-steel
12
stents
11
coronary
9
non-invasive evaluation
8
attenuation alteration
8
differences cobalt-chromium
8
ccta
7
stent
6
fourth update
4

Similar Publications

Rationale: The biodegradable polymer BioMatrix Alpha™ stent contains biolimus A9 drug which is sirolimus derivative increase in lipophicity. The biodegradable polymer sirolimus eluting Combo™ stent is a dual-therapy sirolimus-eluting and CD34+ antobody coated stent capturing endothelial progenitor cells (EPCs).

Hypothesis: The main hypothesis of the SORT OUT XI trial was that the biodegradable polymer biolimus A9 BioMatrix Alpha ™ stent is noninferior to the biodegradable polymer sirolimus eluting Combo™ stent in an all-comers population with coronary artery disease undergoing percutaneous coronary intervention (PCI).

View Article and Find Full Text PDF

Virtual 3D reconstruction of complex congenital cardiac anatomy from 3D rotational angiography.

3D Print Med

January 2025

Department of Pediatric Cardiology, The Heart Institute, University of Colorado, Children's Hospital Colorado, 13123 E 16th Ave B100, 80045, Aurora, CO, USA.

Background: Despite advancements in imaging technologies, including CT scans and MRI, these modalities may still fail to capture intricate details of congenital heart defects accurately. Virtual 3D models have revolutionized the field of pediatric interventional cardiology by providing clinicians with tangible representations of complex anatomical structures. We examined the feasibility and accuracy of utilizing an automated, Artificial Intelligence (AI) driven, cloud-based platform for virtual 3D visualization of complex congenital heart disease obtained from 3D rotational angiography DICOM images.

View Article and Find Full Text PDF

Coronary artery disease remains a significant global health issue and is a leading cause of mortality. Dual antiplatelet therapy, including clopidogrel, is essential for preventing stent thrombosis after coronary artery stenting. This study assessed the comparative efficacy and safety of generic versus brand-name clopidogrel in a large Taiwanese cohort.

View Article and Find Full Text PDF

Kounis syndrome also known as allergic myocardial infarction, represents the simultaneous occurrence of acute coronary syndromes with allergic or hypersensitivity reactions. We present a case of a 58-years-old male who developed anaphylaxis following a leech bite, leading to myocardial infarction despite the absence of prior allergic history. He was entubated and cardiopulmonary resusciation had been performed for 10 minutes.

View Article and Find Full Text PDF

Background And Aims: When dealing with severely calcified lesions in endovascular therapy (EVT) for lower extremity artery disease (LEAD), navigating through severely calcified chronic total occlusion (CTO) using hard-tip guidewires can be challenging. To address this issue, we employed a novel highly intensive penetration (HIP) technique. This technique involves modifying the tail of a 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!