Purpose: The primary aim of the study was to examine stability and alignment after total knee arthroplasty (TKA) using patient-specific instrumentation (PSI) and conventional instrumentation (CI). The hypothesis was that stability and alignment would be better using PSI than CI, 12 months postoperatively. The secondary aim included the evaluation of clinical outcomes after TKA.
Methods: In this prospective randomized controlled trial, 42 patients with knee osteoarthritis received a Genesis II PS prosthesis with either PSI or CI. Patients visited the hospital preoperatively and postoperatively after 6 weeks and 3 and 12 months. To evaluate stability, varus-valgus laxity was determined in extension and flexion using stress radiographs 12 months postoperatively. Three months postoperatively, a long-leg radiograph and CT scan were obtained to measure hip-knee-ankle (HKA) alignment and component rotation. Furthermore, frontal and sagittal alignment of the components, the Knee Society Score, VAS Pain, VAS Satisfaction, Knee injury and Osteoarthritis Outcome score, Patella score (Kujala), University of California Los Angeles activity score, anterior-posterior laxity, (serious) adverse device-related events, and intraoperative complications were reported. The clinical outcomes were compared using independent t tests or non-parametric alternatives, and repeated measurements ANOVA with a significance level of p < 0.05.
Results: No significant differences were found between the two groups regarding stability, HKA angle, and rotational alignment. In four patients, the PSI did not fit correctly on the tibia and/or femur requiring intraoperative modifications. Both groups improved significantly over time on all clinical outcomes, with no significant differences between the groups 12 months postoperatively. The PSI group showed less tibial slope than the patients in the CI group [PSI 2.6° versus CI 4.8° (p = 0.02)]. Finally, the PSI group more frequently received a thinner insert size than the CI group (p = 0.03).
Conclusions: Patients operated with PSI did not differ from CI in terms of stability and alignment. However, in the PSI group ligament releases were more often required intraoperatively. Furthermore, the two methods did not show different clinical results. It seems that the preoperative planning for the PSI facilitates more conservative bone cuts than CI, but whether this is clinically relevant should be investigated. Since PSI is more expensive and time consuming than CI, and does not outperform CI with regard to clinical results, we recommend to use CI.
Level Of Evidence: I.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00167-017-4792-3 | DOI Listing |
Science
January 2025
Beijing Key Laboratory for Theory and Technology of Advanced Battery Materials, Key Laboratory of Polymer Chemistry and Physics of Ministry of Education, School of Materials Science and Engineering, Peking University, Beijing, China.
One of the primary challenges in commercializing perovskite solar cells (PSCs) is achieving both high power conversion efficiency (PCE) and sufficient stability. We integrate wafer-scale continuous monolayer MoS buffers at the top and bottom of a perovskite layer through a transfer process. These films physically block ion migration of perovskite into carrier transport layers and chemically stabilize the formamidinium lead iodide phase through strong coordination interaction.
View Article and Find Full Text PDFPLoS Comput Biol
January 2025
Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, Missouri, United States of America.
Cell collectives, like other motile entities, generate and use forces to move forward. Here, we ask whether environmental configurations alter this proportional force-speed relationship, since aligned extracellular matrix fibers are known to cause directed migration. We show that aligned fibers serve as active conduits for spatial propagation of cellular mechanotransduction through matrix exoskeleton, leading to efficient directed collective cell migration.
View Article and Find Full Text PDFMol Biol Evol
December 2024
Computational Biology and Bioinformatics, Université Libre de Bruxelles, 1050 Brussels, Belgium.
Determining the impact of mutations on the thermodynamic stability of proteins is essential for a wide range of applications such as rational protein design and genetic variant interpretation.Since protein stability is a major driver of evolution, evolutionary data are often used to guide stability predictions. Many state-of-the-art stability predictors extract evolutionary information from multiple sequence alignments (MSA) of proteins homologous to a query protein, and leverage it to predict the effects of mutations on protein stability.
View Article and Find Full Text PDFLangmuir
January 2025
State Key Laboratory of Photon-Technology in Western China Energy, International Collaborative Center on Photoelectric Technology and Nano Functional Materials, Institute of Photonics & Photon Technology, Northwest University, Xi'an 710127, China.
Electrokinetic (EK) flow is a type of flow driven or manipulated by electric body forces, influenced by various factors such as electric field intensity, electric field form, frequency, electric permittivity/conductivity, fluid viscosity, etc. The diversity of dimensionless parameters, such as the electric Rayleigh number, complicates the comparison of the EK flow stability. Consequently, comparing the performance and cost of micromixers or reactors based on EK flow is challenging, posing an obstacle to their industrial and engineering applications.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Department of Psychiatry, University of Magdeburg,, Magdeburg, Sachsen-Anhalt, Germany.
Background: To support diagnosis of Alzheimer's disease (AD), concentrations of Aβ, tTau and pTau(181) and the Aβ/Aβ ratio are determined in cerebrospinal fluid (CSF). To increase standardization and comparability between diagnostic laboratories, certified reference material (CRM) is used to evaluate the trueness of novel assays. Due to lack of CRMs for tTau, pTau(181), and Aβ, comparability may be assessed by comparing assays from different manufacturers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!