Nonlocal total variation based on symmetric Kullback-Leibler divergence for the ultrasound image despeckling.

BMC Med Imaging

Guangdong Provincial Key Laboratory of Medical Image Processing, School of Biomedical Engineering, Southern Medical University, Guangzhou, 510515, People's Republic of China.

Published: November 2017

Background: Ultrasound imaging is safer than other imaging modalities, because it is noninvasive and nonradiative. Speckle noise degrades the quality of ultrasound images and has negative effects on visual perception and diagnostic operations.

Methods: In this paper, a nonlocal total variation (NLTV) method for ultrasonic speckle reduction is proposed. A spatiogram similarity measurement is introduced for the similarity calculation between image patches. It is based on symmetric Kullback-Leibler (KL) divergence and signal-dependent speckle model for log-compressed ultrasound images. Each patch is regarded as a spatiogram, and the spatial distribution of each bin of the spatiogram is regarded as a weighted Gamma distribution. The similarity between the corresponding bins of the two spatiograms is computed by the symmetric KL divergence. The Split-Bregman fast algorithm is then used to solve the adapted NLTV object function. Kolmogorov-Smirnov (KS) test is performed on synthetic noisy images and real ultrasound images.

Results: We validate our method on synthetic noisy images and clinical ultrasound images. Three measures are adopted for the quantitative evaluation of the despeckling performance: the signal-to-noise ratio (SNR), structural similarity index (SSIM), and natural image quality evaluator (NIQE). For synthetic noisy images, when the noise level increases, the proposed algorithm achieves slightly higher SNRS than that of the other two algorithms, and the SSIMS yielded by the proposed algorithm is obviously higher than that of the other two algorithms. For liver, IVUS and 3DUS images, the NIQE values are 8.25, 6.42 and 9.01, all of which are higher than that of the other two algorithms.

Conclusions: The results of the experiments over synthetic and real ultrasound images demonstrate that the proposed method outperforms current state-of-the-art despeckling methods with respect to speckle reduction and tissue texture preservation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5704627PMC
http://dx.doi.org/10.1186/s12880-017-0231-7DOI Listing

Publication Analysis

Top Keywords

ultrasound images
16
synthetic noisy
12
noisy images
12
nonlocal total
8
total variation
8
based symmetric
8
symmetric kullback-leibler
8
kullback-leibler divergence
8
images
8
speckle reduction
8

Similar Publications

Recurrent acute pancreatitis (RAP) affects 15-36% of children with acute pancreatitis (AP) and may progress to chronicity. To determine the etiology and evolution of RAP, a descriptive retrospective cohort study was conducted in patients aged 1-18 years. Twelve patients with RAP were included out of 79 with AP, and demographic, etiological, clinical, analytical, and imaging data were collected.

View Article and Find Full Text PDF

ECG Patterns of Occlusion Myocardial Infarction: A Narrative Review.

Ann Emerg Med

January 2025

Department of Emergency Medicine, University of Minnesota, Minneapolis, MN; Department of Emergency Medicine, Hennepin Healthcare, Minneapolis, MN.

The traditional management of acute coronary syndrome has relied on the identification of ST-segment elevation myocardial infarction (STEMI) as a proxy of acute coronary occlusion. This conflation of STEMI with acute coronary occlusion has historically overshadowed non-ST-segment elevation myocardial infarction (NSTEMI), despite evidence suggesting 25% to 34% of NSTEMI cases may also include acute coronary occlusion. Current limitations in the STEMI/NSTEMI binary framework underscore the need for a revised approach to chest pain and acute coronary syndrome management.

View Article and Find Full Text PDF

Evaluation of a Deep Learning Denoising Algorithm for Dose Reduction in Whole-Body Photon-Counting CT Imaging: A Cadaveric Study.

Acad Radiol

January 2025

Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).

Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.

Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).

View Article and Find Full Text PDF

Application of Diagnostic Imaging in Exotic Animal Gastroenterology.

Vet Clin North Am Exot Anim Pract

January 2025

Avian and Exotic Pet Service, UQ Veterinary Medical Centre, Building 8156, Main Drive, University of Qld, Gatton, Queensland 4343, Australia. Electronic address:

Imaging of an exotic animal with gastroenteric disease is often essential to make a diagnosis. The selection of a modality and its effective use needs careful consideration in each case. Obtaining a high-quality image and its interpretation are an acquired skill.

View Article and Find Full Text PDF

Plasma D-Dimer Changes and Clinical Value in Acute Lower Extremity Deep Venous Thrombosis Treated with Catheter-Directed Thrombolysis.

J Vasc Surg Venous Lymphat Disord

January 2025

Department of Vascular Surgery, Chenzhou First People's Hospital and the First Affiliated, Hospital of Xiangnan University, Chenzhou, Hunan Province 423000, China. Electronic address:

Objective: This study sought to investigate the changes in plasma D-dimer levels during catheter-directed thrombolysis (CDT) in patients with acute lower extremity deep venous thrombosis (DVT), analyze imaging results, and assess their clinical implications.

Methods: We retrospectively analyzed 62 patients diagnosed with acute lower extremity DVT who underwent CDT between March 2019 and December 2022. Plasma D-dimer levels were measured before CDT, at regular intervals after CDT, and at the end of CDT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!