Caffeine is an adenosine receptor antagonist and a possible cause of inadequate stress perfusion. Splenic switch-off (SSO) and splenic rest-stress T1-mapping have been proposed as indicators of stress adequacy during perfusion cardiac magnetic resonance (CMR). We compared myocardial rest-stress T1-mapping with SSO and splenic rest-stress T1-mapping in patients with and without recent coffee intake. We analyzed 344 consecutive patients suspected of myocardial ischemia with adenosine perfusion CMR. All 146 normal CMR studies with a normal T1-rest of the myocardium, used as standard of reference, were included and divided in two groups. 22 patients accidentally ingested coffee < 4 h before CMR, compared to control group of 124 patients without self-reported coffee intake. Two independent readers graded SSO visually. T1-reactivity (ΔT1) was defined as percentual difference in T1-rest and T1-stress. Follow-up data were extracted from electronic patients records. In patients with recent coffee intake SSO was identified in 96%, which showed no significant difference with SSO in controls (94%, p = 0.835), however event rates were significantly different (13.6 and 0.8%, respectively (p < 0.001), median FU 17 months). Myocardial ΔT1 in the coffee group (- 5.2%) was significantly lower compared to control (+ 4.0%, p < 0.001), in contrast to the splenic ΔT1 (- 3.7 and - 4.0%, p = 0.789). The splenic T1-mapping results failed to predict false negative results. SSO and splenic rest-stress T1-mapping are not reliable indicators of stress adequacy in patients with recent coffee intake. Therefore, the dark spleen sign does not indicate adequate myocardial stress in patients with recent caffeine intake. Myocardial rest-stress T1-mapping is an excellent indicator of stress adequacy during adenosine perfusion CMR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5859139PMC
http://dx.doi.org/10.1007/s10554-017-1274-0DOI Listing

Publication Analysis

Top Keywords

rest-stress t1-mapping
12
splenic switch-off
8
sso splenic
8
splenic rest-stress
8
disagreement splenic
4
switch-off myocardial
4
t1-mapping
4
myocardial t1-mapping
4
t1-mapping caffeine
4
caffeine intake
4

Similar Publications

Cardiac stress T1-mapping response and extracellular volume stability of MOLLI-based T1-mapping methods.

Sci Rep

June 2021

University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, John Radcliffe Hospital, Level 0, Oxford, OX3 9DU, UK.

Stress and rest T1-mapping may assess for myocardial ischemia and extracellular volume (ECV). However, the stress T1 response is method-dependent, and underestimation may lead to misdiagnosis. Further, ECV quantification may be affected by time, as well as the number and dosage of gadolinium (Gd) contrast administered.

View Article and Find Full Text PDF

The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis.

J Cardiovasc Magn Reson

June 2020

Department of Cardiovascular Sciences, University of Leicester and the NIHR Leicester Cardiovascular Biomedical Research Unit, Glenfield Hospital, Leicester, LE1 9HN, UK.

Background: Identifying coronary artery disease (CAD) in patients with end-stage renal disease (ESRD) is challenging. Adenosine stress native T1 mapping with cardiovascular magnetic resonance (CMR) may accurately detect obstructive CAD and microvascular dysfunction in the general population. This study assessed the feasibility and reliability of adenosine stress native T1 mapping in patients on haemodialysis.

View Article and Find Full Text PDF

To demonstrate the potential for differentiating normal and diseased myocardium without Gadolinium using rest and stress T1-mapping. Patients undergoing 1.5T magnetic resonance imaging (MRI) as part of clinical work-up due to suspicion of coronary artery disease (CAD) were included.

View Article and Find Full Text PDF

Disagreement between splenic switch-off and myocardial T1-mapping after caffeine intake.

Int J Cardiovasc Imaging

April 2018

Center for Medical Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1 EB 45, Groningen, The Netherlands.

Caffeine is an adenosine receptor antagonist and a possible cause of inadequate stress perfusion. Splenic switch-off (SSO) and splenic rest-stress T1-mapping have been proposed as indicators of stress adequacy during perfusion cardiac magnetic resonance (CMR). We compared myocardial rest-stress T1-mapping with SSO and splenic rest-stress T1-mapping in patients with and without recent coffee intake.

View Article and Find Full Text PDF

Early-stage heart failure with preserved ejection fraction in the pig: a cardiovascular magnetic resonance study.

J Cardiovasc Magn Reson

September 2016

Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9/P, 8036, Graz, Austria.

Article Synopsis
  • The study explores the use of DOCA-salt-treated pigs as a large animal model to investigate early-stage heart failure with preserved ejection fraction (HFpEF) by assessing cardiovascular function through magnetic resonance imaging.
  • Five DOCA pigs and seven control pigs underwent detailed imaging to analyze various cardiac structures and functions, including left ventricular and atrial performance, myocardial mass, and blood flow dynamics.
  • Results showed significant differences in left ventricular mass and wall thickness in DOCA pigs compared to controls, along with elevated atrial volumes, indicating structural changes associated with HFpEF.