Purpose: To describe the use of collagen-based alternatives to cyanoacrylate glue for the sealing of acute corneal perforations.
Methods: A collagen analog comprising a collagen-like peptide conjugated to polyethylene glycol (CLP-PEG) and its chemical crosslinker were tested for biocompatibility. These CLP-PEG hydrogels, which are designed to act as a framework for corneal tissue regeneration, were then tested as potential fillers in ex vivo human corneas with surgically created full-thickness perforations. Bursting pressures were measured in each of 3 methods (n = 10 for each condition) of applying a seal: 1) cyanoacrylate glue with a polyethylene patch applied ab externo (gold standard); 2) a 100-μm thick collagen hydrogel patch applied ab interno, and 3) the same collagen hydrogel patch applied ab interno supplemented with CLP-PEG hydrogel molded in situ to fill the remaining corneal stromal defect.
Results: Cyanoacrylate gluing achieved a mean bursting pressure of 325.9 mm Hg, significantly higher than the ab interno patch alone (46.3 mm Hg) and the ab interno patch with the CLP-PEG filler (86.6 mm Hg). All experimental perforations were sealed effectively using 100 μm hydrogel sheets as an ab interno patch, whereas conventional ab externo patching with cyanoacrylate glue failed to provide a seal in 30% (3/10) cases.
Conclusions: An ab interno patch system using CLP-PEG hydrogels designed to promote corneal tissue regeneration may be a viable alternative to conventional cyanoacrylate glue patching for the treatment of corneal perforation. Further experimentation and material refinement is required in advance of clinical trials.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ICO.0000000000001459 | DOI Listing |
Br J Hosp Med (Lond)
December 2024
Department of Interventional Diagnosis and Treatment, The First Affiliated Hospital of Shihezi University, Shihezi, Xinjiang, China.
This study aims to evaluate the safety and efficacy of α-n-butyl-2-cyanoacrylate (NBCA) glue in comparison with traditional embolization materials for the treatment of acute renal hemorrhage. A total of 105 patients with the acute renal hemorrhage who underwent superselective renal artery embolization were enrolled. The patients were divided into two groups based on the embolization materials used: the traditional group (43 cases, control group) and the medical glue group (62 cases, observation group).
View Article and Find Full Text PDFEndosc Ultrasound
December 2024
Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei Province, China.
Ann Emerg Med
January 2025
Children's Hospital of Eastern Ontario Research Institute, Ottawa, ON, Canada; Department of Pediatrics, Children's Hospital of Eastern Ontario, University of Ottawa, Ottawa, ON, Canada. Electronic address:
Study Objective: The peripheral intravenous catheter (IV) is the most common and painful invasive medical device in acute care settings. Our objective was to determine whether adding skin glue to secure IVs reduced catheter failure rate in children.
Methods: We conducted a randomized controlled trial in a tertiary-care pediatric emergency department (ED).
Cureus
December 2024
Radiology, Saveetha Medical College and Hospital, Saveetha Institute of Medical and Technical Sciences (SIMATS) Saveetha University, Chennai, IND.
Introduction Cosmetic surgery has advanced significantly, with wound closure techniques crucial for determining aesthetic and healing outcomes. Recently, cyanoacrylate glue and subcuticular sutures have gained attention for their unique benefits in cosmetic procedures. Cyanoacrylate glue, a non-invasive tissue adhesive, facilitates faster wound closure with minimal trauma, while subcuticular sutures offer durable, concealed closures, particularly suited for areas under mechanical stress.
View Article and Find Full Text PDFJ Nippon Med Sch
January 2025
Department of Radiology, Nippon Medical School.
As a blood flow control technique for embolization using glue (n-butyl cyanoacrylate; NBCA) for peripheral artery aneurysm/pseudoaneurysm, we placed a vascular plug or coils at the proximal inflow vessel before glue injection. We describe this maneuver, which we call the glue in lockdown technique. Four peripheral aneurysms-two pulmonary artery pseudoaneurysms, one pancreaticoduodenal arcade pseudoaneurysm, and one internal iliac artery aneurysm-deemed unsuitable for conventional embolization because of abnormal blood flow, coagulopathy, or anatomical complexity were embolized with our technique.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!