Design of two-column batch-to-batch recirculation to enhance performance in ion-exchange chromatography.

J Chromatogr A

Department of Chemical Engineering, Centre for Chemistry and Chemical Engineering, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden. Electronic address:

Published: January 2018

AI Article Synopsis

  • Preparative liquid chromatography is crucial for producing high-purity fine chemicals and pharmaceuticals, but traditional methods struggle with balancing product purity and performance.
  • This study explores a two-column batch-to-batch recirculation technique, resulting in significant yield and productivity increases—yield up from 45.4% to 93.6% and productivity rising 3.4 times compared to single-column methods.
  • Although more complex, the recirculation process improves separation efficiency by recycling impure product, reducing losses while achieving higher purity during cyclic steady-state operation.

Article Abstract

Preparative liquid chromatography is a separation technique widely used in the manufacturing of fine chemicals and pharmaceuticals. A major drawback of traditional single-column batch chromatography step is the trade-off between product purity and process performance. Recirculation of impure product can be utilized to make the trade-off more favorable. The aim of the present study was to investigate the usage of a two-column batch-to-batch recirculation process step to increase the performance compared to single-column batch chromatography at a high purity requirement. The separation of a ternary protein mixture on ion-exchange chromatography columns was used to evaluate the proposed process. The investigation used modelling and simulation of the process step, experimental validation and optimization of the simulated process. In the presented case the yield increases from 45.4% to 93.6% and the productivity increases 3.4 times compared to the performance of a batch run for a nominal case. A rapid concentration build-up product can be seen during the first cycles, before the process reaches a cyclic steady-state with reoccurring concentration profiles. The optimization of the simulation model predicts that the recirculated salt can be used as a flying start of the elution, which would enhance the process performance. The proposed process is more complex than a batch process, but may improve the separation performance, especially while operating at cyclic steady-state. The recirculation of impure fractions reduces the product losses and ensures separation of product to a high degree of purity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2017.11.035DOI Listing

Publication Analysis

Top Keywords

process
9
two-column batch-to-batch
8
batch-to-batch recirculation
8
ion-exchange chromatography
8
single-column batch
8
batch chromatography
8
process performance
8
recirculation impure
8
process step
8
proposed process
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!