A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimization of imaging protocols for myocardial blood flow (MBF) quantification with F-flurpiridaz PET. | LitMetric

AI Article Synopsis

  • The study evaluates a new PET tracer, F-flurpiridaz, focusing on how to best estimate myocardial blood flow (MBF) using quantitative methods from dynamic PET data and tracer kinetic modeling.
  • Researchers simulated various infusion times (ITs) of F-flurpiridaz to analyze the time activity curves (TACs) and used a compartmental model to determine 'true' MBF, revealing that a 30-second IT results in the least percentage error in MBF estimation.
  • Results indicate that the most effective imaging protocol for accurate MBF assessment is a 30-second infusion time combined with about 42 updates in the OS-EM reconstruction algorithm, highlighting that both too

Article Abstract

The new PET tracer, F-flurpiridaz, with high myocardial extraction allows quantitative myocardial blood flow (MBF) estimation from dynamic PET data and tracer kinetic modeling. The goal of this study is to determine the optimal imaging protocols and parameters using a realistic simulation study. The time activity curves (TACs) of different tissue organs from a 30-s infusion time (IT) of F-flurpiridaz in a dynamic PET study were extracted from a previous study. The TACs at different time points were incorporated in a series of realistic 3D XCAT phantoms from which the parameters of a 2-compartment model and the 'true' MBF of F-flurpiridaz were determined. The compartmental model was used to generate TACs from 7 additional ITs. PET projection data from the XCAT phantoms were generated using Monte Carlo simulation. They were reconstructed using an OS-EM reconstruction algorithm with different update number (N) to obtain dynamic PET images. The blood and myocardial TACs were derived from the dynamic images from which the MBF and %MBF error was estimated. The %MBF error decreases with increasing N of the OS-EM and levels off after ∼42. The 30-s IT gave the smallest %MBF error that decreases from ∼0.57% to ∼19.40%. The MBF for 2-min, 4-min, 8-min and 16-min IT were statistically significant different from the MBF for 30-s IT (P<0.05). Too fast or too slow infusion time gave higher %MBF error. The optimal imaging protocol in dynamic F-flurpiridaz PET for accurate quantitative MBF estimation was 30-s IT and N of ∼42 for the OS-EM.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2017.08.002DOI Listing

Publication Analysis

Top Keywords

dynamic pet
12
%mbf error
12
imaging protocols
8
myocardial blood
8
blood flow
8
flow mbf
8
xcat phantoms
8
error decreases
8
mbf
6
pet
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!